Level flashing feature, Dim feature, Cruise feature – Code 3 CELS control box User Manual
Page 11: Arrowstik feature

11
3-Level Flashing Feature
Flash patterns are based on the 600-series lightbar software (where a single set of the 7 combinations of 3-level inputs configures the entire bar,
instead of configuring/flashing in pairs). This feature will flash Supervisor and Citadel heads, as well as XT4 and PAR36 heads (primaries only if
secondaries are configured as Takedowns). Patterns available are:
Defaults: L1 default is pattern 10, L2 default is pattern 2, L3 default is pattern 9.
All patterns above are alternating except VAR RATE SNGL, which is picket fence. Cycle flash patterns will consist of NFPA Quad, Var Rate SGL,
Fast SGL, Slow Double patterns from the same column.
ArrowStik activation will override all other Citadel outputs. Rear Cutoff activation will override Citadel flashing outputs. If XT4 and PAR36 secondaries
are configured as Takedowns, then Takedown Steady activation will override both XT4 and PAR36 primaries.
Dim Feature
Dim will dim all outputs that are currently being activated by another function, to 25%, except Supervisor Takedowns. Dim will not affect Cruise func-
tion.
Cruise Feature
Packages 1 & 2: Cruise lights will turn on the Citadel secondary-color end outputs (heads 1 and 6) and additional (PAR36 and XT4) secondary
outputs.
Packages 3 & 4: Cruise lights will turn on the Citadel primary-color end outputs (heads 1 and 6) and additional (PAR36 and XT4) secondary outputs.
The heads will be turned on at 12.5% duty cycle. This function is not programmable. Cruise functionality will be overridden by any other feature/input
being active, except Dim and Rear Cutoff, which have no effect on Cruise.
ArrowStik Feature
This feature will be enabled for Packages 1-4.
The Citadel primary-color (i.e. ArrowStik) outputs will behave as a normal lightbar 6-head ArrowStik.
ArrowStik activation will override the Citadel ArrowStik as well as dual-color (i.e. flashing rear) outputs.
Flash patterns will be the standard 800-series and 950-series patterns. Default will be Mode 1, Medium speed for all four flash pattern types.
Packages 1 Thru 4
1 NULL FLASH All off
2 NFPA QF 75fpm
Supervisor, Citadel, Additional
3 SLOW QF 60fpm
Supervisor, Citadel, Additional
4 FAST SGL 375fpm
Supervisor, Citadel, Additional
5 SLOW SGL 60fpm
Supervisor, Citadel, Additional
6 FAST DBL 115fpm
Supervisor, Citadel, Additional
7 SLOW DBL 60fpm
Supervisor, Citadel, Additional
8 VAR RATE SGL
Supervisor, Citadel, Additional
9 CYCLE
Supervisor, Citadel, Additional
10 NFPA QF 75fpm
Front: Supervisor, Additional
11 FAST SGL 375fpm
Front: Supervisor, Additional
12 SLOW DBL 60fpm
Front: Supervisor, Additional
13 VAR RATE SGL
Front: Supervisor, Additional
14 CYCLE
Front: Supervisor, Additional
Package 5
1 NULL FLASH All off
2 NFPA QF 75fpm
Front, Rear
3 SLOW QF 60fpm
Front, Rear
4 FAST SGL 375fpm
Front, Rear
5 SLOW SGL 60fpm
Front, Rear
6 FAST DBL 115fpm
Front, Rear
7 SLOW DBL 60fpm
Front, Rear
8 VAR RATE SGL
Front, Rear
9 CYCLE
Front, Rear
10 NFPA QF 75fpm
Front
11 FAST SGL 375fpm
Front
12 SLOW DBL 60fpm
Front
13 VAR RATE SGL
Front
14 CYCLE
Front