3-Level Flashing Feature

Flash patterns are based on the 600-series lightbar software (where a single set of the 7 combinations of 3-level inputs configures the entire bar,

instead of configuring/flashing in pairs). This feature will flash Supervisor and Citadel heads, as well as XT4 and PAR36 heads (primaries only if

secondaries are configured as Takedowns). Patterns available are:

Defaults: L1 default is pattern 10, L2 default is pattern 2, L3 default is pattern 9.
All patterns above are alternating except VAR RATE SNGL, which is picket fence. Cycle flash patterns will consist of NFPA Quad, Var Rate SGL,

Fast SGL, Slow Double patterns from the same column.
ArrowStik activation will override all other Citadel outputs. Rear Cutoff activation will override Citadel flashing outputs. If XT4 and PAR36 secondaries

are configured as Takedowns, then Takedown Steady activation will override both XT4 and PAR36 primaries.

Dim Feature

Dim will dim all outputs that are currently being activated by another function, to 25%, except Supervisor Takedowns. Dim will not affect Cruise func-

tion.

Cruise Feature

Packages 1 & 2: Cruise lights will turn on the Citadel secondary-color end outputs (heads 1 and 6) and additional (PAR36 and XT4) secondary

outputs.

Packages 3 & 4: Cruise lights will turn on the Citadel primary-color end outputs (heads 1 and 6) and additional (PAR36 and XT4) secondary outputs.
The heads will be turned on at 12.5% duty cycle. This function is not programmable. Cruise functionality will be overridden by any other feature/input

being active, except Dim and Rear Cutoff, which have no effect on Cruise.

ArrowStik Feature

This feature will be enabled for Packages 1-4.

The Citadel primary-color (i.e. ArrowStik) outputs will behave as a normal lightbar 6-head ArrowStik.

ArrowStik activation will override the Citadel ArrowStik as well as dual-color (i.e. flashing rear) outputs.

Flash patterns will be the standard 800-series and 950-series patterns. Default will be Mode 1, Medium speed for all four flash pattern types.

Packages 1 Thru 4

1 NULL FLASH All off

2 NFPA QF 75fpm

Supervisor, Citadel, Additional

3 SLOW QF 60fpm

Supervisor, Citadel, Additional

4 FAST SGL 375fpm

Supervisor, Citadel, Additional

5 SLOW SGL 60fpm

Supervisor, Citadel, Additional

6 FAST DBL 115fpm

Supervisor, Citadel, Additional

7 SLOW DBL 60fpm

Supervisor, Citadel, Additional

8 VAR RATE SGL

Supervisor, Citadel, Additional

9 CYCLE

Supervisor, Citadel, Additional

10 NFPA QF 75fpm

Front: Supervisor, Additional

11 FAST SGL 375fpm

Front: Supervisor, Additional

12 SLOW DBL 60fpm

Front: Supervisor, Additional

13 VAR RATE SGL

Front: Supervisor, Additional

14 CYCLE

Front: Supervisor, Additional

Package 5

1 NULL FLASH All off

2 NFPA QF 75fpm

Front, Rear

3 SLOW QF 60fpm

Front, Rear

4 FAST SGL 375fpm

Front, Rear

5 SLOW SGL 60fpm

Front, Rear

6 FAST DBL 115fpm

Front, Rear

7 SLOW DBL 60fpm

Front, Rear

8 VAR RATE SGL

Front, Rear

9 CYCLE

Front, Rear

10 NFPA QF 75fpm

Front

11 FAST SGL 375fpm

Front

12 SLOW DBL 60fpm

Front

13 VAR RATE SGL

Front

14 CYCLE

Front