Maintenance, For 'l4 & 'l6 models only, For 'l6 models only – Code 3 MasterCom B Series User Manual

Page 13

Advertising
background image

13

-For 'L4 & 'L6 Models Only-

WARNING LIGHTS 3 LEVEL PROGRESSIVE SLIDE SWITCH:

POSITION 1 - Supplies power to Lighting Level 1, illuminates Green LED and activates LightAlert if supplied.

POSITON 2 - Supplies power to Lighting Levels 1 & 2. illuminates Green & Yellow LED's and activates
LightAlert and SirenLock options if supplied.

POSITION 3- Supplies power to Lighting Levels 1,2, & 3. Illuminates Green, Yellow, and Red LED's; and
activates LightAlert and SirenLock if supplied.

Auxiliary Switches:

AUXILIARY SWITCH "A" - Supplies power to the load connected to terminal SW A.

AUXILIARY SWITCH "B" - Supplies power to the load connected to terminal SW B.

AUXILIARY SWITCH "C" - Operates circuit connected to terminals SWC NO, SWC NC, SWC COM.
Optional functions a momentary activation or a 5 sec. timed switch.

AUXILIARY SWITCH "D" - Supplies power to the load connected to terminal SW D.

-For 'L6 Models Only-

AUXILIARY SWITCH "E" - Supplies power to the load connected to terminal SW E.

AUXILIARY SWITCH "F" - Supplies power to the load connected to terminal SW F.

NOTE: All switches have their own individual LED indicating that the circuit is On. All switches will activate
the LightAlert feature if it is supplied.

LightAlert - The LightAlert option will produce an audible "beep" on a periodic basis if the Warning Light
Switch or any of the Auxiliary Switches are on. A rear accessible circuit board mounted DIP switch is
provided to defeat this option.

SirenLock - The SirenLock, when not defeated by means of a rear panel accessible switch, allows siren tones
(Wail, Yelp, and Hi-Lo) to be produced only when the Warning Light Switch is in the Lighting Level 2 (Green and
Yellow LED's) or Lighting Level 3 (Green, Yellow, and Red LED's) position (switch selectable via a rear panel
accessible switch). Air Horn, Radio Rebroadcast, and Public Address are unaffected by this option.

MAINTENANCE

Your Code 3

®

3890 series siren has been designed to provide trouble free service. In case of difficulty, see

Troubleshooting (page 14,15 ). Also check for shorted or open wires. The primary cause of short circuits
has been found to be wires passing through firewalls, roofs, etc. If further difficulty persists, contact the
factory for troubleshooting advice or return instructions. Public Safety Equipment, Inc. maintains a complete
parts inventory and service facility at the factory and will repair or replace (at the factory's option) any unit
found to be defective under normal use and in warranty. Any attempt to service a unit in warranty by anyone
else other than a factory authorized technician without express written consent by the factory, will void the
warranty.
Units out of warranty can be repaired at the factory for a nominal charge on either a flat rate or parts and
labor basis. Contact the factory for details and return instructions. Public Safety Equipment, Inc. is not
liable for any incidental charges related to the repair or replacement of a unit unless otherwise expressly
agreed to in writing by the factory.

Advertising