Cabletron Systems Smart 04-0053-01 User Manual
Page 42

2-24 SmartSwitch ATM User Guide
Creating an Emulated LAN
IP Over ATM and LANE
6.
On switch SW3, use the
set lnnistatus
command to enable LNNI and SCSP (Server Cache
Synchronization Protocol).
SW3 # set lnnistatus
LNNIStatus(Disabled) : enable
SCSPStatus(Disabled) : enable
SW3 #
Note
SCSP does not have to be enabled for an LES to take part in LNNI. However,
without SCSP enabled, ARP server information is not shared. As a result, client
connects may be slowed by the client’s need to broadcast to find the LES with the
appropriate ARP information.
7.
On SW3, use the
start les
command to activate the switch’s LES and BUS.
SW3 # start les
NOTICE - 'ZLESSRV' ***** LES started *****
SW3 #
Once the LES/BUS is started, it registers with each LECS running LNNI on the network. In turn, the LECS’
communicate the LES/BUS’ existence to all other distributed LES/BUS’ participating in LNNI. Finally, the LES/BUS
on SW3 begins exchanging server cache information (through SCSP) with other LNNI LES/BUS’.