Parts list, Troubleshooting, Changing flash patterns – Code 3 SuperVisor with Torus User Manual

Page 4: Led fusing considerations, Warning

Advertising
background image

7

6

Parts List

LED Fusing Considerations

Although the average current draw per module is very low, due to the type of circuit used to power each module,

the instantaneous peak current to a module can be significantly higher during low voltage conditions. To avoid

prematurely blowing ATO style fuses or tripping breakers it is recommended the following rule-of-thumb be used

to size fuses or breakers. This is especially important in lightbars with many LED modules running off a single

fused source.
Minimum fuse size calculation: (See Wiring Diagram page 5)

For LED 12 volt electrical current only

Troubleshooting

All SuperVisorTLs are thoroughly tested prior to shipment. However, should you encounter a problem during instal-

lation or during the life of the product, follow the guide below for information on repair and troubleshooting. Ad-

ditional information may be obtained from the factory technical help line at 314-996-2800. Follow the guide below

TROUBLESHOOTING GUIDE

Note: LED modules must be replaced as a module. There are no user serviceable parts.

PROBLEM

LED module not

operating when

powered.

QUESTIONS

POSSIBLE CAUSE

a. Bad power/ground

connection.

b. Defective module.

SOLUTION

a. Fix connection.

b. Replace module

N/A

Torus 3LED PCB

Changing Flash Patterns

To change the flash patterns on the LED Light Heads, remove the mounting screws that attach the SuperVisor's Cover

to the Outer Panel to gain access to the printed circuit boards inside (see the exploded view on page 10). Momentarily
short and release the pattern change prongs as shown below to change patterns.

Carefully replace the SuperVisor's

Cover over the Outer Panel and replace the Cover Mounting Screws.

Note: Be extremely careful to replace the wiring such that you don't pinch a wire when you replace

the SuperVisor's Cover. Test the unit to be sure that it works properly.

This Product contains high intensity LED devices. To prevent eye

damage, DO NOT stare into light beam at close range.

wARNINg!

JP1

Flash Pattern Header for

1. Momentarily short and release

to change patterns
2. Hold for 5 seconds to reset the

flash pattern to the first pattern


Directional Module Flash Pattern - Table 2

Cycle Flash-70 - (DEFAULT)

Variable

Flash Single

NFPA Quad Flash-80

Cycle Flash-150

Quad Flash-70

Five Flash-150

Steady Burn Quad Flash-150

Five Flash-70 Triple Flash-150

Triple Flash-70 Double Flash-150

Double Flash-70 Single Flash-150

Single Flash-70 Single Flash-250

Quad Pop Flash-70 Single Flash-375

Advertising