Code 3 XP 9500 User Manual

Page 5

Advertising
background image

5

LED MODULES

The LED modules are available as “flashing” and “stationary” versions. The stationary versions can
be flashed by connecting the module(s) to any flasher that does not require ground through the load
(example: Code 3® 925 or 700 series relay flasher). The flashing modules will have "Cycleflash"
as the standard pattern. Flash patterns can be changed by shorting the 2-pin header, J1 as shown
in Figure 3, momentarily then releasing. Table 1 shows the available patterns and the order when
stepping through patterns. The module can be reset to "Cycleflash" by shorting the header for
greater than 5 seconds and releasing.

FIGURE 3

Directional Module Flash Pattern - Table 1

Flash Pattern

Description

Cycle Flash

Cycles through various patterns @ 70 fpm

Steady-Burn

Steady-Burn

Five Flash

Five Pulses per flash @ 70 fpm

Quad Flash

Four Pulses per flash @ 70 fpm

Triple Flash

Three Pulses per flash @ 70 fpm

Double Flash

Two Pulses per flash @ 70 fpm

Fast Double Flash

Two Pulses per flash @ 85 fpm

NFPA

Four Pulses, 70% Duty Cycle @ 75 fpm

Quad Pop Flash

Four Pulses per flash ( 3 equal, 1 extended) @ 70 fpm

Triple Pop Flash

Three Pulses per flash ( 2 equal, 1 extended) @ 70 fpm

J1

PCB

Momentarily short and release
to change patterns

Advertising