063-GP 11/06
Measure from wall to wall over top of both jambs and cut
header (C) to that measurement.
Position header so that long leg is toward inside of
shower. Lower into place over jambs and panel.
OUTSIDE OF SHOWER
Header
In-Line Panel
Long Leg of
Header
faces inside
of shower
B
Jamb
4
Header
(C)
C
D
Double Channel
Wall
Measure
B
Jamb
Jamb
B
Wall
Slide magnetic strip (H) into slot on magnetic door
stop (F). Trim ends even with door stop using scissors.
Choose which will be the opening side of your door.
Door is normally installed to open on side nearest to
showerhead.
Slide magnetic door stop into jamb or double channel
on opening side of door, making certain that magnetic
strip faces outside of shower.
OUTSIDE OF SHOWER
Header
In-Line Panel
Magnetic Strip
(facing outside
of shower)
C
H
Double
Channel
F
Jamb
B
D
5
Magnetic Door Stop
(F)
Magnetic
Door Stop
If magnetic strips do not seal tightly, reverse polarity
by removing strip from door stop and replacing it
with the previous top end as the bottom end.
Jamb
B
Header
C
Hinge Door Stop
(attached to door)
Slide hinge door stop, which is attached to door panel,
into jamb/double channel on opposite side from
magnetic door stop. For safety purposes, door should
be installed to open out from shower.
OUTSIDE OF SHOWER
6
Hinge Door Stop / Door Panel
Door