I N S T A L L A T I O N
Routing Cables
Version 2
Model 200iP/250iP Motorcycle Pit Dynamometer Installation Guide
2-33
5
Connect the battery and starter cables.
5a
Attach the brown cable to the positive (+) battery post.
5b
Attach the red battery cable to the positive (+) battery post and to the large
stud on the starter solenoid.
5c
Attach the blue and yellow cable to the negative (-) battery post.
5d
Attach the black battery cable to the negative (-) battery post and to the
grounding location on the starter brace.
5e
Attach the blue cable to the starter solenoid.
Figure 2-35: Connect the Battery and Starter Cables
battery
brown cable
blue/yellow cable
red cable
black cable
blue cable
starter solenoid
starter brace
battery cable