Checking test point four—left outflow – Dynojet Flow Meter User Manual

Page 16

Advertising
background image

Flow Meter User Guide

F L O W M E T E R
Flow Meter Testing

12

C

HECKING

T

EST

P

OINT

F

OUR

—L

EFT

O

UTFLOW

Testing the outflow allows you to determine the efficiency of the left pump head.
1

Remove the left outflow hose from the left outflow catch bottle.

2

Attach the left outflow hose to the bottom port of the flow meter.

3

Turn the air pump on.

4

Record the flow meter reading in a data table on page 16.
If the flow meter reading is below the testing range, rebuild the pump head.
Pump head rebuild kits (P/N 79190003) are available from Dynojet.
Note: Dynojet recommends rebuilding both pump heads at the same time.

5

Turn the air pump off.

6

Replace the left outflow hose into the left outflow catch bottle.

Figure 9: Test Point Four—Left Outflow

outflow hose

bottom port

left side of air pump

looking from the bottle

side

right side of air pump

looking from the

bottle side

catch bottle