Checking test point five—right outflow – Dynojet Flow Meter User Manual

Page 17

Advertising
background image

U S E R G U I D E

Flow Meter Testing

Version 1

Flow Meter User Guide

13

C

HECKING

T

EST

P

OINT

F

IVE

—R

IGHT

O

UTFLOW

Testing the outflow allows you to determine the efficiency of the right pump head.
1

Remove the right outflow hose from the right outflow catch bottle.

2

Attach the right outflow hose to the bottom port of the flow meter.

3

Turn the air pump on.

4

Record the flow meter reading in a data table on page 16.
If the flow meter reading is below the testing range, rebuild the pump head.
Pump head rebuild kits (P/N 79190003) are available from Dynojet.
Note: Dynojet recommends rebuilding both pump heads at the same time.

5

Turn the air pump off.

6

Replace the right outflow hose into the right outflow catch bottle.

Figure 10: Test Point Five—Right Outflow

bottom port

outflow hose

left side of air pump

looking from the

bottle side

right side of air pump

looking from the

bottle side

catch bottle

Advertising