Power supply of the appliance, Using of appliance, Bpss-6129 – Dyras BPSS-6129 User Manual

Page 6

Advertising
background image

EN

BPSS-6129

BPSS-6129

10

11

With pressing the MEM button you can choose between the two storage places, then you can move on with
pressing the START/STOP button.

First you can set up the month, then the day, the hours (AM=morning,
PM=afternoon) and the minutes. You can increase the figures with
pressing the MEM button and you can move on to the next function with
the START/STOP button.

When you have finished with the set-up, please, switch off the apparatus
with holding the START/STOP button.

Putting on the air cuff of the blood pressure monitor:

Connect the cuff to the appliance, by plugging the pump connector
(subassembly number 8) into the socket (subassembly number 7) (Make
sure there is a good fit.)

Remove all clothing from your upper arm, because the cuff of the blood
pressure monitor must make good contact with the skin.

Sit at a table where you can comfortably support your lower arm so that
your left arm, where the blood pressure is measured, would be at the
height of your heart.

Place the arm cuff of the blood pressure monitor so that the tube leads
to the pump, and its side with the Velcro is on the outside and pull it
through the metal frame. Fold back the Velcro end of the arm cuff round
the frame.

Slip your left hand through the arm cuff and pull the cuff onto your upper
arm.

The tube of the arm cuff must face the inside part of the arm and the
bottom edge of the arm cuff should be 1-2 cm above the elbow.

Fix the arm cuff tightly on the upper arm with the Velcro in the position
described above, so that it cannot slip and no gap remains between the
upper arm and the arm cuff.

Rest your hand on the table with your palm upwards, and your fingers
loosely bent during the whole measurement time.

How to measure blood pressure

In order to obtain characteristic measured values, please do not perform strong physical work or exercise,
but rest for 5-10 minutes. Do not eat, drink and smoke directly before or while making measurements. Some
abnormalities e.g. arrhythmia or fibrillation can cause incorrect measurement results.

POWER SUPPLY OF THE APPLIANCE

The apparatus can be supplied with batteries (Mignon, AA, LR6) or an adapter. An accumulator cannot be used for
supply. Please, use only those EN60601-1 and EN60601-1-2 standard compliant adapters which are suitable for
providing DC 6 V, 1 A.

Never use an adapter and a battery at the same time. If you would like to operate the apparatus with an adapter,
please, remove the batteries before that.

In the case of using an adapter, please, connect the adapter to the apparatus, then plug the adapter into the wall
socket.

In the case of using batteries, please, follow the steps below:

1. Please, push the lid of the battery holder in the direction of the arrow, then remove it from the battery

holder.

2. Insert the batteries in the battery holder according to the marked polarity.

3. Finally replace the cover of the battery holder and check its position.

A warning indication on the display appears when the battery requires changing:

If you do not use the appliance for a longer period of time, please remove the batteries from the battery holder,
because corrosive electrolyte can possibly escape and damage the appliance. (The manufacturer accepts no
responsibility for appliances damaged this way.) To avoid this harmful phenomenon please absolutely observe
the following:

Please always insert the batteries with the correct polarity (+ and -) according to the marks on the battery
holder.

Never use spent and new batteries at the same time.

Never use batteries of different make and type at the same time.

Spent batteries must be replaced immediately with new ones. If you do not use the appliance for a longer
period of time, please remove the batteries from the battery holder.

Please never dispose of spent batteries in the household waste - for environmental reasons, but take them to
a designated collecting point.

USING OF APPLIANCE

Date and time setup, selection of storage place

With the apparatus turned off press and hold the START/STOP button for 3-4 seconds until the symbol of the
storage place begins to blink on the display.

User'sManual BPSS-6129.indd 10-11

User'sManual BPSS-6129.indd 10-11

2012.10.30. 10:24:46

2012.10.30. 10:24:46