Can system installation, Can system – EFCO 403 Series Storefront User Manual

Page 82

Advertising
background image

EFCO CORPORATION 1/2013 PART NO. Y001

Page 82 of 94

Series 401,402, & 403 Installation Instructions






























































These recommendations are for general erection procedures only. For
actual job conditions, see the details on the shop drawings. For perimeter
anchor type and spacing, refer to the approved shop drawings or consult

the project design professional

.

Locate 1/4" diameter weep holes at quarter points of each D.L.O. at the sill can

members into a bead of sealant in the sill receptor.

Seal the inside of the receptor to the condition at the jamb and set the jamb

receptor as shown below.

- CAN SYSTEM

the condition must be level and flat within 1/8", otherwise shims will be required.

The can receptor at the head and sill is intended to be installed without shims, but

material preps for the can receptor system.

Be familiar with typical storefront installation procedures before proceeding with any

SECTION IV: F.

PREPARATION / INSTALLATION

The cut length formula for the can receptor is horizontal rough opening minus 1/2".

The can receptor system does not accommodate door jambs. If doors are a

requirement, a standard shear block storefront system will have to be used.

The use of end caps are at the discretion of the architect / general contractor.

Exterior and interior perimeter seals are mandatory with this can system.

The cut length formula for jambs and verticals is frame dimension minus .825".

Tip up the jamb in place being sure the

sill end is set in sealant maintaining a

perimeter seal between jamb, sill can, and

the condition. Fasten the jamb in place

using 1/4" diameter minimum fastener on

16" centers.

Snap-in the head and sill can fillers, locating
them tight against the jamb member.

Rotate the first vertical in place in the sill can,
locating the vertical tight against the previous can fillers. The can fillers will

hold the vertical on center line.

Apply a bead of sealant to the

receiving race for the can filler prior

to installing the filler. Fill this cavity
completely to ensure an adequate
seal. Clean off any excess.

Set the sill and head receptor can with 1/4" diameter minimum fasteners,
4" from jambs and verticals and then 16" on centers.

Seal over all fasteners (typ.).

If end caps are being incorporated,

install them now with sealant at the
ends of the receptor can.

1)

2)

3)

4)

5)

6)

7)

8)

9)

10)

11)

12)

13)

14)

15)

16)

Fig. #96

W

EE

P

W

EE

P

W

EE

P

1/4

P

OI

NT

S

W

EE

P

Advertising
This manual is related to the following products: