Series 406x storefront installation instructions – EFCO 406X Series User Manual
Page 11

Series 406X Storefront Installation Instructions
EFCO 2014
Page 11
Section 3B. Shear Block Fabrication (cont.)
Shear Block Horizontals
21U7 Shown, also for open
back and tubular intermediate
horizontals.
Use Drill Fixture #DJ52
placed at each end of
horizontal as shown.
Use a .230” dia. No. 1 drill bit
for each hole.
DJ52
21U7
F734
DJ52
21U4Shear Block
Horizontals
Use Drill Fixture
#DJ47 placed at
each end of
horizontal as
shown.
Drill one side as in
Fig. 8a then flip
drill fixture to
opposite side as in
Fig. 8b.
Use a .230” dia.
No. 1 drill bit for
each hole.
(a)
(b)
DJ47
DJ47
21U4
F757
F722
F722
F757
Vertical Dead Load Shear Pins
Use Drill Fixture #DJ48 placed on vertical as shown below.
Left Hands Shown, Right Hands Opposite
Use a .189” dia. No. 12 drill bit at darkened hole only.
DJ48
DJ48
Fig. #8
Fig. #7
Fig. #9