Dc voltage table – transistors and diodes – Elecraft KX1 Manual User Manual
Page 93

E-6
DC Voltage Table – Transistors and Diodes
NOTES: Measurements were made with a 50-ohm dummy load connected and a supply voltage of 13 V. The 30- meter option
was installed (KXB30) and the ATU was removed (KXAT1). In general, your measurements should be within 10% of the values
shown. Pins NOT listed in the table should indicate 0.0 volts DC. Pins marked with (*) are hard to measure due to noise
pickup. Shaded areas show transmit-mode measurements (using TUNE).
Ref. Pin VDC Ref. Pin VDC Ref. Pin VDC Ref. Pin VDC Ref. Pin VDC
D1 A 13.33
Q1 D 13.5 Q7 B 0.7
(on)
K
10.4
G
0.34
C
*
D2
A
13.8
S
1.77
Q8
B
4.39
K
13.5
Q2
D
4.44
C
5.61
D3
A
9.0
G
3.44
E
3.74
K
13.5
S
4.44
Q9
B
0.3*
D4
K
0.3*
Q3
D
4.45
C
1.39
D5
K
5.8
G
3.44
E
0*
D6
K
5.8
S
4.45
D7 K 13.5 Q4 E 0.23
B
0.94
C
2.14
Q5
E
2.24
B
2.14
C
13.5
Q6
C
13.5