Elecraft KPA100 Manual User Manual

Page 26

Advertising
background image

26

Tap

D I S P L AY

to check the K2 power supply voltage (E) and

current (i). If the voltage is lower than expected, or the current is over
0 . 5 0

amps, refer to Troubleshooting (page 64 of this appendix). Note:

Installing the KPA100 increases K2 receive-mode current drain by
approximately 100-200 mA. In transmit mode, additional current is
drawn, but this will not be included in the voltage/current display.

Tap

D I S P L AY

until the frequency display returns.

Set your DMM for DC volts, 20 or 30 V full scale (or auto ranging).

Connect the DMM's (-) probe to the ground jumper on the KPA100 board
(near U1). Using the DMM's (+) probe, make the voltage measurements
listed below. Voltages should be within +/- 10% except as noted.

i

When making measurements at IC pins, be careful not to

short adjacent pins. Use only a fine-tip DMM probe. Do not attempt
to make measurements using a wire or a probe with a large, blunt tip.


KPA100 Test Point (+)

Voltage

U1 pin 1

5.0

U1 pin 7

0 to 0.1

U1 pin 13

0 to 0.1

U1 pin 14

0 to 0.1

U1 pin 15

0 to 0.1

U1 pin 20

5.0

U1 pin 27

5.8

U1 pin 28

5.7

U2 pin 10

12-15

U4 pin 1

12-15

U4 pin 11

5.0

U5 pin 1

0 to 0.1

U5 pin 7

0 to 0.1

U6 pin 6

0 to 0.5

Tap

M E N U

, then tap

D I S P L AY

to bring up the K2's secondary

menu (SEC will be flashed). This menu is used to configure various
features that are available in K2 revision 2 firmware.

Use the VFO knob or the

B AN D +

/

B AN D -

switches to scroll to the

P A

menu entry. If you see PA -- , the KPA100 microcontroller is

not communicating properly with the K2. Refer to Troubleshooting.

The PA parameter will probably be set to OFF initially. Hold

E D I T

to highlight the parameter, then scroll until you find an entry starting with
E

(error status). The error status should be E12, where 1 indicates that

the KPA100 is in bypass (QRP) mode, and 2 indicates that no KPA100
power supply is present. If you see any other error numbers, see Error
Status
in the Troubleshooting section.

Set the PA parameter to ON. Tap

M E N U

to return to menu scroll

mode.

Tap

D I S P L AY

to return to the primary menu (PRI will be flashed).

Tap

M E N U

again to return to the normal frequency display.

Turn off the K2 and disconnect the power supply.

Disconnect the KPA100 end of the ribbon cable.