ETS-Lindgren 2005 Single Axis Positioner User Manual
Page 24

24 |
Assembly and Installation
•
Thread the conduit penetration and DB-9 connector through the hole
on the shield, making sure that the circular gasket presses against the
shield
•
Hold the conduit nut on the inside of the filter in order to have the
washer and nut installed from the inside of the shielded room. Two
people may be necessary to perform this step.
•
Screw the brass nut on the conduit penetration and tighten by hand.
Using an adjustable wrench, apply an additional ¼ of a turn clockwise
to the brass nut. Do not apply excessive torque to the brass nut.
•
Self drilling screws, provided by the customer, may be used to mount
the filter to the shielded wall by its mounting holes. Other means
include screw and nut by a through hole on the shield. Mounting
screws and nuts should be tightened so that there are no gaps
between the filter and shield where the screws penetrate the shield.
This will insure a proper RF seal.