ETS-Lindgren 2005 Single Axis Positioner User Manual
Page 28

28 |
Operation
Model 2005 Azimuth Positioner Command Set
Command
Format
Example
Description
Set Speed (0-3)
SX (x = 0,1,2,3)
S1
Sets speed for AP:
S0 = 0.25 rpm
S1 = 0.5 rpm
S2 = 1 rpm
S3 = 2 rpm
Query Speed
S?
Returns speed setting
(0-3)
Continuous
Rotation
CR
In the continuous mode
of operation the AP is
allowed infinite
movement. The AP
travels from 0 – 359.9
and the limits are
ignored
Non-continuous
Rotation
NCR
In the non-continuous
mode, the AP motion is
restricted between the
upper and lower limits
Stop
ST
Set Position
CPxxx.x
(x = 000.0--999.9)
CP180.0
Sets the current
position to the specified
value
Read Position
CP?
Queries the current
position in degrees
Move CW
CW
Move
clockwise
Move CC
CC
Move
counter
clockwise
Set CW Limit
ULxxx.x
(x = 000.0--999.9
UL 359.9
Sets upper limit in non-
continuous mode.
Query CW Limit
UL?
Returns CW limit