Setti

ng alarm values

The setup of each alarm consists of the level of the threshold, of the triggering edge, of the release
ti me aft er the alarm and the relay selecti on (Kit 2). If the threshold is set to OFF, briefl y pressing
goes to the setti ng up of the next alarm.

Threshold level

The maximum threshold value depends on the selected unit but corresponds to 150 km/h.
Decrementi ng the value to obtain OFF will de-acti vate the alarm.
Triggering edge

The trigger edge determines whether the measurement must be higher (rising edge -

max

) or

lower (falling edge -

min

) than the threshold for the alarm to be triggered.

Durati on of acti vati on

When an alarm is acti vated, it will be turned off when the alarm conditi ons are not met for x
seconds.
The ti mes to be selected are: 0 s, 10 s, … 60 s, -- (infi nite; the alarm will not be automati cally
cancelled).
Selecti on of relay

(only Kit 2)

The desired relay can be selected depending on the alarm. It is possible for several alarms to operate the same relay.

Setti

ng the unit

The measurement unit for wind speed can be selected from the following units: km/h, mph, knots, m/s and fps.

Adjusti ng the special parameters
The special parameters are the model of wind turbine and the acti vati on of the acousti c signal.

The turbine model

The turbine model determines the turbine calibrati on used by the instrument. In general for the SKYWATCH AWS, the model
Pr1 should be selected. The other turbine models are used for specifi c installati ons.
Acousti c signal

The acousti c signal can be turned on or not (saving energy) for 1 minute when an alarm occurs.

Setti

ng up the relays (only Kit 2)

The inacti ve state of each relay can be selected from no (normally open) and nc (normally closed).

ADVANCED FUNCTIONS

To access the advanced functi ons of SKYWATCH AWS, press the 3 butt ons

+

, and

for a certain ti me.

Mode OFF
The instrument is turned off : no measurements are carried out and the alarm thresholds are not tested. The alarm programming
is not modifi ed.
ON: Press the butt on for 2 seconds.

Self-test
The instrument tests the display, the acousti c signal and the LEDs.

Reset
The instrument can be initi alised to its factory setti ngs on confi rmati on by pressing the butt on .

Version
The version ID of the instrument is displayed for 2 seconds.

Level

Edge

Length

Relay

OFF

Alarm n

OFF

Test

Version

+

+

+

Reset ?

Yes

No

+

Main display

0.5 s

2 s

4 s

6 s

8 s

Butt on-press