Refrigerant Access Valves and Hose Connectors

DIA.

REF.

2

2

DIA.

MIN. DIA.

EXACT

DATUM DIA.

.1693

.210-36UNS-1MOD.P.D. TH'D.

.189

.181

.192

.197

.4091

.3941

MIN.FULL

TH'D DEPTH

.293

3

1

1

17°±30'

INCL. ANGLE

.168

.155

.150

.551

1
2

3

Counterbore and/or Chamfer Optional.

This Diameter Must Be Concentric With Pitch

Diameter Of Internal Th'd. Within .003 T.I.R.

1/4" SAE Flare External Dimensions To

Conform To ANSI/SAE J513f "Refrigeration

Tube Fittings"

Figure 2

TYPICAL BODY DIMENSIONS

CONVERSION TABLES

INCHES

MILIMETERS

.875

22.2

.551

14.0

.4091

10.39

.3941

10.01

.308

7.82

.293

7.44

.189

4.80

.181

4.60

.1719

4.366

.1693

4.300

.168

4.27

.155

3.94

.150

3.81

.109

2.77

.076

1.93

.064

1.63

.035

0.89

.025

0.64

.010

0.25

.003

0.08

DEGREES

RADIANS

17°30'

0.3054

16°30'

0.2880

IN.LBS.

CM.KG.

1-1/2

1.7

3

3.5

.1719 DIA.

BALL

EXACT

DATUM DIA.

.1693

.4091

.3941

.308

.293

ANSI/ARI Standard 720-97 used by permission

Figure 3

TYPICAL CORE DIMENSIONS

Figure 4

PLUG GAGE

VALVE

SEAL

REF.

CORE

SEAL

.025

.076

.064

DIA.

.206-36 UNS-1

MOD. TH'D.

REF.

.109

4

.875

MAX.

4

Sealing Materials to Be Compatible

with Halogenated Hydrocarbon

Refrigerants and Refrigerant Oil For

The Intended Application.

Section 5. Dimensions and Materials

Figure 5

BALL GAGE

ACCESS VALVE BODY GAGING PROCEDURES

Dimensions In Inches

5.1Dimensions . See Figures 2 and 3 (above).

5.1.1 While conformance to Figures 2 and 3 is

recommended, where components do not meet the

constructional and dimensional requirements

shown, all access valves shall still interchange with

components that meet these requirements and

shall comply with all mandatory requirements to be

in conformance with this standard.

5.2Materials. Materials used for the seals on the valve

core shall be compatible for service with halogenated

hydrocarbon refrigerants and refrigerant oil for the

intended application.

Section 6. Gaging Procedures

6.1

Gaging. Figures 4 and 5 (above) show two

accepted methods of gaging the access valve body.

Section 7. Voluntary Conformance

7.1

Conformance. While conformance with this

standard is voluntary, conformance shall not be

claimed or implied for products or equipment within its

Purpose (Section 1) or Scope (Section 2) unless such

claims meet all of the requirements of the standard.

APPENDIX A. References-Normative

A1

Listed here are all standards, handbooks, and other

publications essential to the formation and

implementation of the standard. All references in this

appendix are considered as part of the standard.

A1.1 ANSI/SAE Standard J513f-MAY94,

Refrigeration Tube Fittings , 1994, American

National Standards Institute/Society of Automotive

Engineers, 11 West 42nd Street, New York, NY

10036, U.S.A./400 Commonwealth Drive,

Warrendale, PA 15096, U.S.A.
A1.2 ASHRAE Terminology of Heating, Ventilation,

Air Conditioning and Refrigeration, American

Society of Heating, Refrigerating and Air-

Conditioning Engineers, Inc., 1791 Tullie Circle

N.E., Atlanta, GA 30329, U.S.A.

APPENDIX B. References-Informative

A1

None.

REFRIGERANT ACCESS VALVE DIMENSIONS

1/4" SAE FLARE SIZE

Dimensions In Inches

4301 N. Fairfax Drive, Suite 425, Arlington, VA 22203

Phone: 703-524-8800 Web: www.ari.org

ARI Standard 720-97

TM

JB INDUSTRIES

630.851.9444

Printed in USA
© 2007 J/B Industries Inc.

www.jbind.com
[email protected]