4.2.3
Channel Connection
The following diagrams illustrate the external connection of the CP382 to the application.
Figure 4-1: Digital Output Connection for One Cluster
Figure 4-2: Digital Output Circuit for One Channel
Ch 0
Ch 1
Ch 7
CP382
CON2
+
External
VCC
External VCC
EXTGND
V
LOAD
LOAD
External GND
0
7
1
Supply Voltage
Ch 0
CP382
CON2
External VCC
EXTGND
External GND
Rds, on
LOAD
+
External
VCC
V
0
Supply Voltage