Configuration, Pb-sio4a configuration, 1 pb-sio4a address map and id byte – Kontron PB-SIO4A User Manual

Page 25: 2 vmebus interrupts

Advertising
background image

PB-SIO4A

Configuration

ID 19958, Rev. 0300

Page 3 - 3

® PEP Modular Computers GmbH

3. Configuration

3.1 PB-SIO4A Address Map and ID Byte

The PB-SIO4A is addressed (odd byte access) by using the carrier board base address
and one of the following offsets for the piggyback location:

Piggyback location A ( the upper position on the carrier board)

Base Address + $01

DUART1

Base Address + $21

DUART2

Base Address + $41

ID Byte

Piggyback location B ( the lower position on the carrier board)

Base Address + $81

DUART1

Base Address + $A1

DUART2

Base Address + $C1

ID Byte

The PB-SIO4A has an ID Byte of $E7 (RS422/RS485).

3.2 VMEbus Interrupts

Each DUART device is able to issue an interrupt request (*IRQ) to the carrier board. In
the event of simultaneous interrupt requests those from DUART #1 have priority over
those from DUART #2.

The interrupt level is set by the carrier board. See the carrier board documentation for
setting of the level. The interrupt vector itself is provided by the DUART.

Advertising