Ipmi firmware user guide cp6002 – Kontron CP6002 IPMI User Manual

Page 32

Advertising
background image

IPMI Firmware User Guide

CP6002

Page 32

ID: 1039-1613, Rev. 2.0

Bh /
NNN:IPMB 5V

Voltage (02h) /
Threshold ( 01h)

2204h / 2204h /
1212h

IPMB 5V supply

N

Ch /
NNN:Fan1 Speed

Fan (04h) /
Threshold (01h)

0000h / 0000h /
1B1Bh

Speed [rpm] Fan 1

N

Dh /
NNN:Fan2 Speed

Fan (04h) /
Threshold (01h)

0000h / 0000h /
1B1Bh

Speed [rpm] Fan 2

N

Eh /
NNN:Last Reset

OEM (CFh) /
‘digital’ Discrete (03h)

0002h / 0000h /
0003h

Board reset event

N

Fh /
NNN:Slot System

Entity presence (25h) /
Sensor-specific (6Fh)

0000h / 0000h /
0003h

Board is in System Slot
(SYSEN)

N

10h /
NNN:PCI Present

Entity presence (25h) /
Sensor-specific (6Fh)

0000h / 0000h /
0003h

Board is selected (BDSEL)
and in system slot (SYSEN)

N

11h /
NNN:CTCA chassis

Entity presence (25h) /
Sensor-specific (6Fh)

0000h / 0000h /
0003h

Value is always 1

N

12h /
NNN:Board PwrOff

Power supply (08h) /
‘digital’ Discrete (03h)

0000h / 0000h /
0003h

N

13h /
NNN:IPMI WD

Watchdog2 (23h) /
Sensor-specific (6Fh)

010Fh / 0000h /
010Fh

IPMI Watchdog

Y

/ 010Fh

14h /
NNN:IPMB State

IPMB status change (F1h) /
Sensor-specific (6Fh)

000Fh / 0000h /
000Fh

IPMB-0 state (refer to
PICMG 3.0 Rev 2.0, 3.8.4.1)

N

15h /
NNN:ACPI State

System ACPI Power State
(022h) / Sensor-specific (6Fh)

7FFFh / 0000h /
7FFFh

System ACPI Power State

N

16h /
NNN:Health Error

Platform Alert (24h) /
‘digital’ Discrete (03h)

0000h / 0000h /
0003h

Aggregates states (power,
temperatures etc.).
Visualization by the Health
LED.

N

17h /
NNN:CPU 0 Status

Processor (07h) /
Sensor-specific (6Fh)

0463h / 0400h /
04E3h

CPU status.
Offset 0ah: “Processor
Automatically Throttled”

Y

/ 0402h

18h /
NNN:POST Value

POST value OEM (C6h) /
Sensor-specific (6Fh)

4000h / 0000h /
40FFh

POST code value (port 80h)

N

19h /
NNN:FWH0 BootErr

Boot error (1Eh) /
Sensor-specific (6Fh)

0008h / 0008h /
0008h

Firmware Hub 0 (Boot Flash
0) boot error

Y

/ 0008h

1Ah /
NNN:FWH1 BootErr

Boot error (1Eh) /
Sensor-specific (6Fh)

0008h / 0008h /
0008h

Firmware Hub 1 (Boot Flash
1) boot error

Y

/ 0008h

1Bh /
NNN:XMC present

Entity Presence (25h) /
Sensor-specific (6Fh)

0000h / 0000h /
0003h

Presence of XMC-A board

N

1Ch /
NNN:XMC-2 pres

Entity Presence (25h) /
Sensor-specific (6Fh)

0000h / 0000h /
0003h

Presence of XMC-B board

N

1Dh /
NNN:Pwr Denied

Platform Alert (24h) /
‘digital’ Discrete (03h)

0002h / 0002h /
0003h

1 = o.k., no alert, power not
denied

N

1Eh /
NNN:FRU Agent

OEM FRU Agent (C5h) /
Discrete (0Ah)

0140h / 0000h /
0147h

FRU Initialization Agent
state

Y

/ 0140h

Table 9:

Sensor List

SENSOR Number

/

ID string

SENSOR TYPE (CODE) /

EVENT/READING TYPE

(CODE)

Ass. Mask /

Deass. Mask /

Reading Mask

DESCRIPTION

LED I1on

error /

Reading

Mask

Advertising