Table 11: MCH Analog Sensor Thresholds

SEN

SOR Number

/

ID stri

ng

Lower non recoverable

Lower critical

Lower non

criti

cal

Normal min

Nominal

No

rm

al max

Upper non cri

tical

Upper critical

Upper non recoverable

08h / T

emp Air Inlet

AM4901 /

/ AM5901

-45 °C

-40 °C

-35 °C

5 °C

25 °C

35 °C

55 °C

60 °C

70 °C

0Bh /

Vcc +12V

n.a.

10.64V

n.a.

11

.4 V

12.0 V

12.6 V

n.a.

13.27 V

n.a.

0Ch /

Vcc +3.3

V

n.a.

3.12 V

n.a.

3.12 V

3.3 V

3.46 V

n.a.

3.46 V

n.a.

0Dh /

Vcc +3.3V MMC

n.a.

3.12 V

n.a.

3.12 V

3.3 V

3.46 V

n.a.

3.46 V

n.a.

0Eh/

Vcc +1.2V

n.a

.

4.6

6 V

n.a

.

4.7

0 V

5.0

V

5.3

1 V

n.a

.

5.3

6 V

n.a

.