3 mch analog sensor thresholds, Mch analog sensor thresholds – Kontron AM4901 IPMI User Manual
Page 60
Advertising
IPMI Firmware User Guide
AM5901/AM4901
Page 60
ID: 1035-8760, Rev. 3.0
7.3
MCH Analog Sensor Thresholds
The following table indicates the analog sensor thresholds for the MCH.
Table 11: MCH Analog Sensor Thresholds
SEN
SOR Number
/
ID stri
ng
Lower non recoverable
Lower critical
Lower non
criti
cal
Normal min
Nominal
No
rm
al max
Upper non cri
tical
Upper critical
Upper non recoverable
08h / T
emp Air Inlet
AM4901 /
/ AM5901
-45 °C
-40 °C
-35 °C
5 °C
25 °C
35 °C
55 °C
60 °C
70 °C
0Bh /
Vcc +12V
n.a.
10.64V
n.a.
11
.4 V
12.0 V
12.6 V
n.a.
13.27 V
n.a.
0Ch /
Vcc +3.3
V
n.a.
3.12 V
n.a.
3.12 V
3.3 V
3.46 V
n.a.
3.46 V
n.a.
0Dh /
Vcc +3.3V MMC
n.a.
3.12 V
n.a.
3.12 V
3.3 V
3.46 V
n.a.
3.46 V
n.a.
0Eh/
Vcc +1.2V
n.a
.
4.6
6 V
n.a
.
4.7
0 V
5.0
V
5.3
1 V
n.a
.
5.3
6 V
n.a
.
Advertising