2 hardware sensors, 1 ipmb-l link sensor, Hardware sensors – Kontron AM4320 User Manual

Page 20

Advertising
background image

8

AM4320

www.kontron.com

2.4.2

Hardware Sensors

Table 2-1: Hardware Sensors

X

Exceed critical threshold

*

Power On/Off

-

Power On

N

No change

2.4.2.1

IPMB-L Link Sensor

The AM4320 has an IPMB-L links to communicate with the AMC Carrier and other devices on the IPMB-0 bus.
The MMC monitors the bus for any link failure and sends a bus failure event to the AMC Carrier when the
recovery occurs.

Sensor Name

Voltage/Signals Monitored

Scanning Enabled
under Power
State

Health LED
(Green to Amber)

IPMI Info-1

Internal IPMC firmware diagnostic

*

N

IPMI Info-2

Internal IPMC firmware diagnostic

*

N

FRU Agent

Board FRU Data agent that verify FRU Data validity

*

N

ModuleHotSwap

AMC HS State

*

N

IPMBL State

Operational state of IPMB-L

*

N

MMC Storage Err

Management sub-system health: non volatile memory

error.

*

N

MMC Reboot

IPMC reboot detection

*

N

Ver Change

IPMC firmware upgrade detection

*

N

Temp Board

Board air outlet temperature

*

X

Temp LAN

LAN Temperature

*

X

Temp MMC

MMC Temperature

*

X

Vcc +3.3V SUS

3.3 V management

*

X

Vcc +12V

12 V payload

-

X

Vcc +3.3V

3.3 V

-

X

Vcc +1.2V

1.2V

-

X

V_PUMP

Voltage on board blue LED VPUMP suspend power supply

*

X

Power State

Board State

*

X

Health Error

Board health sensors (aggregation of other sensors)

*

Asserted / De-

asserted

Pres SFP1

SFP1 Presence

-

Pres SFP2

SFP2 Presence