5 keyboard versus num-lock, 2 related application notes, 3 high frequency radiation (to meet en55022) – Kontron MSM800SEL User Manual

Page 42: 1 for peripheral cables, 2 for stack-through applications, Keyboard versus num-lock, Related application notes, High frequency radiation (to meet en55022), For peripheral cables, For stack-through applications

Advertising
background image

MSM800SEV/SEL

/ Detailed System Description

www.kontron.com

40

6.1.5 Keyboard versus NUM-Lock

Without a connected keyboard, the NUM-Lock ON field in the BIOS setup

must not be

activated. Otherwise the time-

out noticeably slows down the reaction speed of the computer as soon as the keyboard is not connected. The PS2
peripherals (KB and MS) are not hot-plug compatible.

6.2 Related Application Notes

Application Notes are available at

http://support.kcc-ag.ch/

or on any KCC Application CD.

6.3 High Frequency Radiation (to meet EN55022)

Since the PC/104 CPU modules are very highly integrated embedded computers, peripheral lines are not protected
against radiation from the high frequency spectrum. To meet a typical EN55022 requirement, all peripherals that go
outside of the computer case must be externally filtered.

Typical signals that must be filtered:

Keyboard:

KBCLK, KBDATA and VCC

Mouse:

MSCLK, MSDATA and VCC

COM1/2/3/4: All serial signals must be filtered
LPT:

All parallel signals must be filtered

CRT:

Red, blue, green, hsynch and vsynch must be filtered

Typical signals that must not be filtered, since they are used internally:

IDE:

Connected to the hard disk

Floppy:

Connected to the floppy

LCD:

Connected to the internal LCD

6.3.1 For Peripheral Cables

Use a filtered version for all DSUB connectors. Select the filter specifications carefully. Place the filtered DSUB
connector directly on the front side and be sure that the shielding makes good contact with the case.

9pin

DSUB connector from AMPHENOL

FCC17E09P

820pF

25pin

DSUB connector from AMPHENOL

FCC17B25P

820pF

6.3.2 For Stack-Through Applications

On each peripheral signal line that goes outside the computer case, place a serial inductivity followed by a grounded
capacitor of 100pF to 1000pF. In this case, no filtered connectors are needed. Place the filter directly under or behind
the onboard connector.