Amp power input – x2/x3, Lvds interface, 11 amp power input – x2/x3 – Kontron MSM-LP Manual User Guide V106 User Manual

Page 21: 12 lvds interface, Fpc connector – x11

Advertising
background image

MSM-LP / MSM-LP Connectors & Jumpers




www.kontron.com

17

3.2.11 AMP Power Input – X2/X3

The AMP power inputs are always connected on the top side of the board.

Header

Nr.

Signal Name

Function

AMP 2.8mm

X3

V5.0_IN

5 Volt power IN

Header

Nr.

Signal Name

Function

AMP 4.75mm

X2

GND

Ground

X2 and X3 not equipped on system board.

3.2.12 LVDS Interface

The LVDS implementation complies with the JILI specification of Kontron (JILI30). When using an LCD, additional
voltages may be required to drive the display logic and supply the backlight converter therefore an additional
connector for supply voltages is provided.

The FPC connector is only mounted on the top side. The corresponding backlight connector is assembled on the
opposite side.

FPC Connector – X11

Header

Pin

Signal Name

Function

Pin

Signal Name

Function

1

FPC_AN

First channel data out A

16

NC

Not connected

2

FPC_AP

First channel data out A

17

GND

Ground

3

FPC_BN

First channel data out B

18

NC

Not connected

4

FPC_BP

First channel data out B

19

NC

Not connected

5

FPC_CN

First channel data out C

20

NC

Not connected

6

FPC_CP

First channel data out C

21

NC

Not connected

7

GND

Ground

22

NC

Not connected

8

FPC_CLKN

First channel clock

23

NC

Not connected

9

FPC_CLKP

First channel clock

24

GND

Ground

10

FPC_DN

First channel data out D

25

SDA

I2C data line

11

FPC_DP

First channel data out D

26

DATAENA

Panel power output

12

NC

Not connected

27

SCL

I2C clock line

13

NC

Not connected

28

VCC

+3.3V power *)

14

GND

Ground

29

VCC

+3.3V power *)

15

NC

Not connected

30

VCC

+3.3V power *)

*) Panel power can be set to +5V by assembly option.

Advertising