3.13.1 BIOS Settings for Fan Control

The fan can be controlled via the BIOS Settings “Advanced Hardware Health Module Hardware Health”

In general 4 modes are possible

» Auto Fan Mode: Temperature Values can be selected to control the Fan

» Fan Always On Full: Fan is always full on

» Fan Disable Mode: Fan is disabled

» Fan Manually Mode: A fixed PWM value (0…255) can be entered to run the fan at a selected speed

The used hardware monitor onboard is an ADT7475. For additional information please refer to the regarding

datasheet

.

3.13.2 Electrical Characteristics

Starting with revision 2.0 there are 2 version of onboard fan control possible. Our standard modules have the simple
version populated. For custom projects it is possible to populate a more sophisticated one. The differences are:

Features

Premium Fan

Base Fan

Input Voltage Range

8.5V - 18V

8.5V - 18V

Output Voltage

5V / 12V

Only 12V (switch in BIOS without function)

Max. output current

1A

0.3A

The premium fan option is only available on moldules with GS45 MCH.

The fan voltage is in both versions VCC of the board and limited to 12V max.

The Fan out voltage output is not short circuit proof. If necessary the user has to ensure
that the circuit is protected externally, for example by a fuse on the backplane.

With premium fan solution it is recommended to select the correct fan voltage first in BIOS
setup and then connect the fan.

To connect a standard FAN with 3pin connector to the module please use adaptor cable
KAB-HSP 200mm (96079-0000-00-0) or KAB-HSP 40mm (96079-0000-00-2)