Table 3-76:

0x390: Carrier Control Register

ACTION

D7

D6

D5

D4

D3

D2

D1

D0

READ

0

0

0

Cntrl4

Cntrl3

Cntrl2

Cntrl1

Cntr0

WRITE

NU

NU

NU

Cntrl4

Cntrl3

Cntrl2

Cntrl1

Cntr0

POWER UP

0

0

0

0

0

0

0

0

BITFIELD

DESCRIPTION

[D0]

Cntr0

Control register for line *con_cb_reset_n*:
'0' = line is deasserted (logic level is HIGH)
'1' = line is asserted (logic level is LOW)

[D1]

Cntr1

Control register for line *con_thermtrip_n*:
'0' = line is deasserted (logic level is HIGH)
'1' = line is asserted (logic level is LOW)

[D2]

Cntr2

Control register for line *con_sus_stat_n*:
'0' = line is deasserted (logic level is HIGH)
'1' = line is asserted (logic level is LOW)

[D3]

Cntr3

Control register for line *con_sus_s3_n*:
'0' = line is deasserted (logic level is HIGH)
'1' = line is asserted (logic level is LOW)

[D4]

Cntr4

Control register for line *con_sus_s4_n*:
'0' = line is deasserted (logic level is HIGH)
'1' = line is asserted (logic level is LOW)