Cooling subsystem, Fan sensors, Fan speed sensors – Kontron S5500 SEL Troubleshooting User Manual

Page 40: 1 fan sensors

Advertising
background image

System Event Log Troubleshooting Guide for Intel

®

S5500/S3420 series Server Boards

Cooling subsystem

Revision 1.0

Intel order number G74211-001

31

5. Cooling subsystem

5.1 Fan sensors

There are three types of fan sensors that can be present on Intel

®

server systems: speed, presence and redundancy. The last two are only

present in systems with hot-swap redundant fans.

5.1.1

Fan Speed Sensors

Fan speed sensors monitor the rpm signal on the relevant fan headers on the platform. Fan speed sensors are threshold-based sensors.
Usually they only have lower (critical) thresholds set, so that a SEL entry is only generated should the fan spin too slowly.

Table 27: Fan Speed Sensors Typical Characteristics

Byte

Field

Description

11

Sensor Type

04h = Fan

12

Sensor Number

30h

– 39h (Chassis specific)

13

Event Direction and
Event Type

[7] Event direction

0b = Assertion Event

1b = Deassertion Event

[6:0] Event Type = 01h (Threshold)

14

Event Data 1

[7:6]

– 01b = Trigger reading in Event Data 2

[5:4]

– 01b = Trigger threshold in Event Data 3

[3:0]

– Event Trigger Offset as described in Table 28

15

Event Data 2

Reading that triggered event

16

Event Data 3

Threshold value that triggered event

The following table describes the severity of each of the event triggers for both assertion and for deassertion.