SHIM

CAP

SCREW

DOR-O-MATIC 2500

9/64"

13/64"

1 13/16"

RIXSON 27 SERIES CLOSERS

PIVOT

SHOE

CAP

BOTTOM

ARM

1 49/64"

INSTALLATION OF OFFSET HUNG DOOR WITH FLOOR CLOSER

D O O R A N D F R A M E

1. Position floor closer using Closer Instruction Template.

CAUTION: Smooth, permanent trouble-free operation of the door

depends on the proper installation of the closer. A Template is

furnished in each floor closer package to give correct position of

center of closer spindle from door and frame, as well as the

proper height for use with or without thresholds.

2. Modify cut-out in door as necessary. (fig. 3 or Closer Template)

3. Fasten bottom arm into door bottom rail.

Assemble pivot shoe, shim (when used) and bottom arm as

shown in figure 2. The 3/8" Shim furnished will satisfy the

requirements of most closers with thresholds. In some

cases, other thicknesses will be required and must be made

by installer.

NOTE: Shoe is drilled right hand and left hand. If threshold is not

to be used, do not install shim.

4. Place frame portion of top pivot in transom bar and secure in

place using 3 screws #12-24 x 5/8" M.S.

5. Set door in frame so that bottom arm engages spindle of floor

closer. Do not tighten locking screw.

6. Depress pin in top door portion pivot and slip under frame

portion until positive engagement is felt. Tighten closer arm

per instructions.

7. Shim closer cement case so that there is 1/8" setback between

exterior face of frame and face of door and 3/32" clearance

between vertical door stiles and frame jambs. Work to 1/8"

between pairs of doors.

8. Adjust vertical clearance to 1/8" between door top rail and

transom bar with adjusting screws or shims as provided in

closer package.

9. When closer is properly positioned, fill space under and around

cement case in rough opening with grout or quick set cement.

(Plaster of Paris is not recommended.)

10. Close door, glaze and adjust as outlined on pages 15 and 25.

Figure 1

Figure 2

Figure 3

24

MAY 2012

D O O R & F R A M E

I N S T A L L A T I O N M A N U A L

Web Address: www.oldcastlebe.com

Phone: 1-866-OLDCASTLE (653-2278)