STEP 2
Cut members to size.
Wall jambs and intermediate vertical mullions are cut to frame height.
Horizontal members are cut to D.L.O.
Snap-on trim is cut D.L.O. minus(-) 1/16"
Glazing bead RW-5134 is cut D.L.O. minus(-) 1/8"
Face covers: Vertical covers are cut to vertical mullion length.
Horizontal covers are cut D.L.O. minus(-) 1/16".
STEP 3
Drill or punch holes in split verticals and wall jambs for attaching horizontals.

4

FEBRUARY 2012

S t o r m M a x R W - 5 1 0 0

TM

I N S T A L L A T I

FRAME FABRICATION

O N M A N U A L

Phone: 1-866-OLDCASTLE (653-2278)