8

REFRIGERANT PIPE CONNECTION

Settlement of outdoor unit

Anchor the outdoor unit with
a bolt and nut 10 or

8 tightly

and horizontally on a concrete
or rigid mount.

Fit the seal into the drain elbow, then insert
the drain joint into the base pan hole of
outdoor unit, rotate 90

to securely assemble

them. Connecting the drain joint with an
extension drain hose (Locally purchased),
in case of the water draining off the outdoor unit
during the heating mode.

Drain joint installation

Seal

Drain joint

Base pan hole of
outdoor unit

Seal

Drain pipe

Fig.13

Refrigerant pipe connection

Oblique

90 C

Roughness

Burr

Main cause for refrigerant leakage
is due to defect in the flaring work.
Carry out correct flaring work
using the following procedure:
A: Cut the pipes and the cable.
1. Use the piping kit accessory or pipes
purchased locally.
2. Measure the distance between the indoor and the outdoor unit.
3. Cut the pipes a little longer than the measured distance.
4. Cut the cable 1.5m longer than the pipe length.

1. Flaring work

Fig.14

A

B

Air inlet

Air outlet

Air inlet

Fig.12

B: Burr removal

1. Completely remove all burrs from the cut
cross section of pipe/tube.
2. Put the end of the copper tube/pipe in a
downward direction as you remove burrs in
order to avoid dropping burrs into the tubing.

Pipe

Reamer

Point down

Fig.15

Outdoor unit dimension
mm(WxHxD)

A(mm)

458

460

B(mm)

250

276

530

290

560

335

549

276

Mounting dimensions

700x535x235

685x430x260

780x540x250

760x590x285

845x695x335