0 appendix, 1 error messages, 2 continuous output (stream) format – Rice Lake 120 Digital Weight Indicator User Manual
Page 33: Appendix, Sp ace> <time> < / > <date> <space> <raw_count

Appendix
29
7.0
Appendix
7.1
Error Messages
Table 7-1.
120
Error Messages
Error Message
Description
Solution
_ _ _ _ _ _
(bottom LED segments lit)
Display overflow (negative)
Negative weight value too large to be
displayed (< –99999)
_ _ _ _ _ _
(middle LED segments lit)
Overload
Weight value exceeds scale capacity
_ _ _ _ _ _
(top LED segments lit
)
Display overflow (positive)
Positive weight value too large to be
displayed (> 999999)
7.2
Continuous Output (Stream) Format
Figure 7-1 shows the continuous output format sent to the 120 EDP or printer port when the STREAM parameter
(SERIAL menu) is set to either EDP or PRN.
<STX> <POL> <wwwwwww> <UNIT> <G/N> <S> <EXTEND> <TERM>
ASCII 02
(decimal)
Polarity:
<Space> = Positive
<–> = Negative
Weight data: 7 digits, right-justified, with
decimal point, leading zero suppression.
Error =
- - - - -
-
L = pounds
K = kilogram
T = ton
G = grams
O = ounces
<space> = none
G = Gross
N = Net
Status:
<space> = valid
I = Invalid
M = In motion
<CR> <LF>
or <CR>
ASCII 13, 10
(decimal)
<SP
ACE> <TIME> < / > <DATE> <SPACE> <RAW_COUNT>
ASCII 32
(decimal)
ASCII 32
(decimal)
ASCII 47
(decimal)
Time: 8 digits, hh:mm:ss
hh: 00–24
mm: 00–59
ss: 00–59
Date: 2 digits, dd
dd: 01–31
Raw count: 8 digits
00000000–16777216
Figure 7-1. Continuous Output Data Format