Rice Lake 920i Installation Manual V3.08 User Manual
Page 116
110
920i
Installation Manual
<wspec [–] [0] digit[[.]digit]>
Scale weight
Weight for the source scale. wspec is defined as follows:
wspec Indicates whether the weight is the current displayed weight
(W, w), gross (G, g), net (N, n), or tare (T, t) weight. Upper-case
letters specify right-justified weights; lower-case are left-justified.
Optional /P, /S, or /T suffixes can be added before the ending
delimiter (>) to specify weight display in primary (/P), secondary
(/S), or tertiary (/T) units.
[–]
Enter a minus sign (–) to include sign for negative values.
[0]
Enter a zero (0) to display leading zeroes.
digit[[.][.]digit]
The first digit indicates the field width in characters. Decimal point
only indicates floating decimal; decimal point with following digit
indicates fixed decimal with n digits to the right of the decimal.
Two consecutive decimals send the decimal point even if it falls at
the end of the transmitted weight field.
<CR>
—
Carriage return
<LF>
—
Line feed
Format Identifier
Defined By
Description
Table 10-8. Custom Stream Format Identifiers