Installation & Operation Manual - Calibration

47

to enter the number of belt revolutions.

Figure 5-2. Enter Number of Revolutions

6. The operator will key in the number of times the belt traveled past the reference point.

7. The integrator will then calculate the pulses per unit of measure. This will be used for displaying the

speed of the belt and totalizing the weight during operation.

8. The number of belt revolutions is stored as the test duration. This value is used for auto calibration when

the integrator is being calibrated to the load cell.

5.2

Integrator Calibration

There are three modes of integrator calibration:

Auto Cal

Material Cal

Zero Cal

All three calibration methods are described in the following sections and are their softkey locations.

Figure 5-3. Calibration Method Softkeys

End

SCALE #1

Home

11/23/2011

08:13AM

96489 Pulse

261 Per Sec

889.25

Time Running

Cancel

Enter Number of Revolutions
=> 1.0

11/23/2011

08:13AM

Exit=>

Test Time

Test Accumulator

Old Span Error %

Auto Cal

Span Error %

13.50

117.4

3574

25.00

Progress

Material

Zero Cal