Specifications
Controls
General:
On, Off, %/WGT, TEST/ZERO, Left Front, Right
Front, Left Rear, Right Rear
Channel selection:
Any combination
Display:
4 digit, LCD (0.5”)
Indicators:
Left Front, Right Front, Left Rear, Right Rear, Low
Battery, Selected %
Electrical
Voltage:
12 VAC/VDC, 120/240 VAC
Batteries:
6 x AA-size disposable alkaline cells or rechargeable Nickel-
Cadmium cells.
Battery Life:
6 - 8 hours on fully recharged Ni-Cad cells. 20-25 hours on
fresh alkaline cells.
Auto Off:
The system will automatically shut off after 1 hour without use
or motion.
Filtering:
Analog: Trans-besel filter
Digital: Average of several internal weights gives steady
readings for unstable loads
Auto-zero: Satisfies all HB-44 requirements
Input:
Input: 4 analog channels
Performance
Speed:
≈
1 sec to typical reading (static)
Accuracy:
±
0.1% of applied load or
±
display graduation, whichever is greater
Divisions:
6000 lb/ 2800 kg capacity: graduation = 1 lb/0.5 kg
8800 lb/ 4000 kg capacity: graduation = 1 lb/0.5 kg
Environmental
Humidity:
10 to 95% non-condensing
Temperature:
Storage: -40
°
C to +75
°
C. / -40
°
F to +170
°
F
Operating -10
°
C to +40
°
C. / +14
°
F to +104
°
F