12

MSI-8000

Operator’s Manual

3.0

User Defined Function Keys

The following function descriptions are for optional user defined functions that are

programmed on the three front panel USER keys (F1,F2 & F3). To enable the USER key

functions, you must set up the USER keys following the procedures in Section 4.0. Note

that Function Key setup on the MSI-8000 is independent of the Function Keys of the

connected Scale/Dyna-Link.

Note

In software release 1-XX, F3 is dedicated to the print function and cannot
be changed. The functions PRINT (F3) and TARE are available full-time on
the MSI-8000 so, although possible, you do not need to program a
Function key for those functions.

Off

No USER Key Function assigned. The F-Key is disabled.

Test

The

TEST

function provides an LCD test that lights all LCD segments and the LEDs, then

the model number (8000), the software version number, the battery level, and then a

display test counting from 00000 to 99999. Other internal tests are performed and if any

test fails an error code will display. See Section 6.2 for a description of all error codes. The

TEST

can be aborted anytime by pushing

ZERO

. The test can also be single stepped by

pushing

F2

and then using the

F1

key to step from display to display.

Total

Note

The Total Mode must be programmed from the Setup Menus before the
USER key will function. See Section 4.1. This feat
ure should not be
confused with the ttl.rd (Total Remote Devices) function, which will add
weight from two or more load sensors.

For accumulation of multiple weighments, the accumulator uses the displayed tension, so

GROSS and NET readings can be added into the same TOTAL.
There are four modes of totalizing: Manual and three Auto Modes.
The Manual Mode requires the TOTAL button to be pressed with the tension on the scale.

The tension will be added to the previously accumulated value. This assures that a weight/

tension on the scale is only added to the total once. Both the manual and three auto total

modes require that the tension on the scale return below 0.5% (relative to full scale) of

GROSS ZERO or NET ZERO before the next weighment can be added. Applied tension

must be >1% of capacity above GROSS ZERO or NET ZERO before it can be totaled.

Manual Total

The

Fx-TOTAL

key under the MANUAL TOTAL mode functions in this manner:

Tension is > 1% of capacity and has not been totaled - Pushing the

Fx-TOTAL

key will add

the current tension to the TOTAL weight. The

Fx

LED blinks to indicate the tension value

was accepted. The TOTAL LCD annunciator and the Total weight is displayed for ~5

seconds and then the number of samples are displayed for ~2 seconds.
Current Tension has been Totaled - Pushing the

Fx-TOTAL

key functions as “View Total”

only and functions as View Total until the 1% threshold is exceeded to allow the next

addition to the total value.