11. Remove the valve fitting by using a 9/16" wrench.
12. Loosen but do not remove the top valve fitting
by using an adjustable wrench .
Prepare Filter and Fittings
13. Prepare fittings with thread seal tape on all
threads using approximately 2 - 2.5 wraps on
each threaded fitting.
14. Unscrew the filter (three pieces)
Attach Filter Assembly
15. Screw the L shaped male fitting onto the air
line fitting.
16. Attach the top cover of the filter with the arrow
facing out towards the front of the battery box
(shown above).
17. Screw the extruded street brass fitting onto the
front portion of the filter top (arrow side).
Direction
of arrow
18. Screw white filter into bottom of the filter cover.