Rice Lake Stationary Livestock Scale - MAS-LC - Load Cell Wiring Revision User Manual
Technical bulletin, Load cell rewire for ag scales
Load Cell Rewire for Ag Scales
Technical Bulletin
Effective 09/17/2013 Rice Lake Weighing Systems started wiring the agricultural scales according to the
Handbook 44 standards. The following illustration shows the updated wiring layout.
Load Cell #1
Load Cell #2
Load Cell #4
Load Cell #3
Scale Cable
Junction Box
Trimmers
Load Cell #4
Load Cell #1Load Cell #2
Load Cell #3
Indicator
Black
Green
White
Shield
Red
+E
-E
+S
-S
GND
V1
V2
V3
V4
Figure 1. Updated wiring layout
230 W. Coleman St. t Rice Lake, WI 54868 t USA
U.S. 800-472-6703 t Canada/Mexico 800-321-6703 t International 715-234-9171 t Europe +31 (0) 88 2349171
www.ricelake.com www.ricelake.mx www.ricelake.eu www.ricelake.co.in m.ricelake.com
Specifications subject to change without notice.
Rice Lake Weighing Systems is an ISO 9001 registered company.
© Rice Lake Weighing Systems
November 12, 2013
159193