Load Cell #1
Load Cell #2
Load Cell #4
Load Cell #3
Scale Cable
Junction Box
Trimmers
Load Cell #4
Load Cell #1Load Cell #2
Load Cell #3
Indicator
Black
Green
White
Shield
Red
+E
-E
+S
-S
GND
V1
V2
V3
V4
Load cell wiring shown is effective for all models
later then 09/17/2013, models built prior that date
s h o u l d r e w i r e t h e s c a l e t o t h e u p d a t e d
configuration. For instructions for rewiring,
d o w n l o a d a d d e n d u m x x x x x x f r o m
www.ricelake.com.
Note
14 Rice Lake Stationary Livestock Scale Operator’s Manual
Figure 4-3. Load Cell Wiring Diagram
D
A
B
Indicator
A
D
C
B
Scale
A -EXC Black
B +SIG Green
C +EXC Red
D -SIG White
Connector
C
Figure 4-4. Scale/Indicator System Connection