Three stage ex500, Push reset button on stage 1 stage 2 and stage 3 – Ring Communications RM5000EX User Manual

Page 45

Advertising
background image

March 2011 Operations Manual RM5000EX

THREE STAGE EX500

Three EX500 are interconnected to form one system. Two to four audio links and one RS485 data

link are used to connect the three centrals.

PROGRAMMING

STAGE 1 (address $08):
1. Default System Memory to Stage 1 with 3 call digits (page 38).
5.

Set Network Address = 08 (page 37)

6.

Push Reset Button

7.

Program Interlinks

Interlink1

Interlink2

Interlink3

Interlink4

Set device type ILK SDT 183 6

SDT 184 6 SDT 185 6

SDT 186 6

Set remote net

SNA 183 4 09

SNA 184 4 09 SNA 185 4 0A SNA 186 4 0A

Set remote line equ. SNA 183 5 3A

SNA 184 5 3B SNA 185 5 3A SNA 186 5 3B

STAGE 2 (address $09):

1. Default System Memory to Stage 2 with 3 call digits (page 38).
2. Set Network Address = 09 (page 37)

3. Push Reset Button
4. Program Interlinks.

Interlink1

Interlink2

Interlink3

Interlink4

Set device type ILK SDT 283 6

SDT 284 6

SDT 285 6

SDT 286 6

Set remote net

SNA 283 4 08

SNA 284 4 08

SNA 285 4 0A

SNA 286 4 0A

Set remote line equ. SNA 283 5 3A

SNA 284 5 3B

SNA 285 5 3C

SNA 286 5 3D

STAGE 3 (address $0A):

1. Default System Memory to Stage 3 with 3 call digits (page 38).
2. Set Network Address = 0A (page 37)

3. Push Reset Button
4. Program Interlinks.

Interlink1

Interlink2

Interlink3

Interlink4

Set device type ILK SDT 383 6

SDT 384 6

SDT 385 6

SDT 386 6

Set remote net

SNA 383 4 08

SNA 384 4 08

SNA 385 4 09

SNA 386 4 09

Set remote line equ. SNA 383 5 3C

SNA 384 5 3D

SNA 385 5 3C

SNA 386 5 3D

Push Reset Button on Stage 1 Stage 2 and Stage 3

Page45

Ring-Master

Advertising