6.

Slide motor/wheel assembly from Plenum. Grasp only the motor casing; do not damage wheel, shaft or other
components on Plenum. Do not rest assembly on wheel.

For the steps following below, refer to diagram C.

7.

Loosen set screw from wheel hub with 5/32” allen wrench.

8.

Twist wheel to loosen and pull off of motor shaft. Wheels
“fused” to shaft may require penetrating oil and/or a wheel
puller to facilitate removal. Discard old wheel when removed.
Important: The housing inlet collar from old motor will
have to be removed and saved for use with the new motor.

For the steps following below, refer to diagram D.

The new motor/wheel with spring ring inlet collar assembly is only compatible with SideShots with date codes after 9518. The following
modifications will have to be made to adapt the motor/wheel assembly to the SideShot with date codes between 9226 and 9517.

9. Loosen set screw with 5/32” allen wrench and remove

wheel from new motor.

10. Remove and save (4) nuts from the new motor mounting

plate and remove from motor. Leave spacers on motor
studs.

11. Remove (2) screws which hold spring ring inlet collar assembly to

mounting plate and discard spring ring inlet collar assembly.

12. Secure motor to mounting plate with (4) nuts removed in

step 10. Important: The capacitor of the motor should be
opposite the flat edge on motor mounting plate.

13. Place inlet collar removed in step 8 over new motor shaft so

embossed edge will be facing wheel cavity, (See Diagram C).

14. Place wheel on new motor shaft with wheel cavity facing motor and firmly tighten set screw on flat of shaft, (See Diagram C).

For the steps following below, refer to diagram B.

15. Install new motor/wheel assembly into Plenum with leads facing electrical box. Use caution when inserting motor/wheel

assembly into Plenum to avoid wheel damage. Firmly fasten motor to plenum using (6) nuts removed in step 5.

16. Line up inlet collar so housing studs go through the collar ring. Note: Inlet ring embossed edge should penetrate into blower

housing. Install and tighten the (2) nuts for the inlet collar which were removed in step 3.

17. Replace plenum access cover plate and tighten (6) nuts removed in step 3.

18. Reinstall motor and electrical box brace screws removed from step 2.

19. Route BLACK and WHITE wires from motor into electrical box . Note: A ground wire is not included on these

replacement motors. The motor is grounded by contact with the Plenum and ground wire from terminal strip to Plenum.

20. Remove 1/4” of insulation from the WHITE wire of motor and connect to “L2” of terminal strip. Connect BLACK motor

lead to “M” of Timer/Relay.

21. Reestablish power and run SideShot through heating cycle to verify proper operation.

P/N: 8504016

©1999 TJERNLUND PRODUCTS, INC. ALL RIGHTS RESERVED

REV. A 11/99

DIAGRAM C

DIAGRAM D

Advertising