Tjernlund HST_HS115_HSUL-J, 1, 2 Series (Discontinued) 8504060 Rev A 11/99 User Manual

Page 12

Advertising
background image

11

HST SERIES CONNECTED WITH 24V THERMOSTAT ON SINGLE ZONE GAS OR OIL EQUIPMENT

HSUL SERIES CONNECTED WITH 24V THERMOSTAT ON SINGLE ZONE GAS EQUIPMENT

NOTE:
Power Venter may operate
independently of burner circuit
when power is initially sup-
plied to L1 and L2 connec -
tions of the Relay/Timer. If the
Power Venter continues to
operate for more than 10 min-
utes without a call for heat,
verify that wiring is in accor-
dance with proper diagram.

HST SERIES CONNECTED WITH SET BACK THERMOSTAT AND ISOLATION RELAY

(NECESSARY IF HST CYCLES ERRATICALLY)

NOTE:

This wiring diagram may not be compatible with certain set-back thermostats. If the Power Venter runs without a call for heat,
(after initial post-purge time delay from 1 -10 minutes), an isolation relay will have to be added to isolate the 4 & 5 coil inputs on
Relay/Timer. See diagram below for wiring with isolation relay.

NOTE:
Power Venter may operate
independently of burner circuit
when power is initially supplied
to L1 and L2 connections of
the Relay/Timer. If the Power
Venter continues to operate for
more than 10 minutes without
a call for heat, verify that
wiring is in accordance with
proper diagram.

Advertising