Switching characteristics, Is shown in, Switching – Cypress CY7C1318CV18-200BZI User Manual

Page 20: Characteristics

Advertising
background image

CY7C1318CV18
CY7C1320CV18

Document Number: 001-07160 Rev. *F

Page 20 of 26

Switching Characteristics

Over the Operating Range

[20, 21]

Cypress

Parameter

Consortium

Parameter

Description

267 MHz

250 MHz

200 MHz

167 MHz

Unit

Min Max Min Max Min Max Min Max

t

POWER

V

DD

(Typical) to the First Access

[22]

1

1

1

1

ms

t

CYC

t

KHKH

K Clock and C Clock Cycle Time

3.75 8.4

4.0

8.4

5.0

8.4

6.0

8.4

ns

t

KH

t

KHKL

Input Clock (K/K and C/C) HIGH

1.5

1.6

2.0

2.4

ns

t

KL

t

KLKH

Input Clock (K/K and C/C) LOW

1.5

1.6

2.0

2.4

ns

t

KHKH

t

KHKH

K Clock Rise to K Clock Rise and C to C Rise

(rising edge to rising edge)

1.68

1.8

2.2

2.7

ns

t

KHCH

t

KHCH

K/K Clock Rise to C/C Clock Rise

(rising edge to rising edge)

0.00 1.68 0.00

1.8 0.00 2.2 0.00 2.7

ns

Setup Times

t

SA

t

AVKH

Address Setup to K Clock Rise

0.3

0.5

0.6

0.7

ns

t

SC

t

IVKH

Control Setup to K Clock Rise (LD, R/W)

0.3

0.5

0.6

0.7

ns

t

SCDDR

t

IVKH

Double Data Rate Control Setup to Clock (K/K)

Rise (BWS

0

, BWS

1

, BWS

2

, BWS

3

)

0.3

0.35

0.4

0.5

ns

t

SD

t

DVKH

D

[X:0]

Setup to Clock (K and K) Rise

0.3

0.35

0.4

0.5

ns

Hold Times

t

HA

t

KHAX

Address Hold after K Clock Rise

0.3

0.5

0.6

0.7

ns

t

HC

t

KHIX

Control Hold after K Clock Rise (LD, R/W)

0.3

0.5

0.6

0.7

ns

t

HCDDR

t

KHIX

Double Data Rate Control Hold after Clock (K/K)

Rise (BWS

0

, BWS

1

, BWS

2

, BWS

3

)

0.3

0.35

0.4

0.5

ns

t

HD

t

KHDX

D

[X:0]

Hold after Clock (K/K) Rise

0.3

0.35

0.4

0.5

ns

Notes

21. When a part with a maximum frequency above 167 MHz is operating at a lower clock frequency, it requires the input timings of the frequency range in which it is being

operated and outputs data with the output timings of that frequency range.

22. This part has an internal voltage regulator; t

POWER

is the time that the power is supplied above V

DD

minimum initially before a read or write operation can be initiated.

[+] Feedback