Aireshare, Model asll wiring connections – Tjernlund ASLL AireShare Level-to-Level Ventilator Rev 03/09 8504156 User Manual

Page 7

Advertising
background image

WIRING

WIRING

Disrupt power at circuit breaker to outlets within the joist/truss cavity you will be working.

1. Wire Blower into 120 VAC power source as shown in wiring connection diagram. NOTE: Optional 120 VAC wall switch or thermostat

may be desired.

2. Attach ASLL electrical box coverplate, (See Diagram N1).

OPTIONAL SURFACE WIRING INSTALLATION

Surface wiring materials can be found at most do-it-yourself hardware and home improvement stores. If wiring to an existing outlet using
surface wiring, it is best to select a joist/truss section that contains an electrical outlet to wire into. If that is not possible, run surface
wiring track horizontal along wall and use a 90 degree track piece to route down to floor in desired location ASLL will be installed, (See
Diagram U).

WARNING: To reduce the risk of fire or electrical shock remove power from outlet at circuit braker before wiring. Use a volt meter to

assure that power is not supplied to outlet before continuing.

1. Mark a vertical level line down center of outlet. Remove or cut out baseboard for surface wiring track, (See Diagram Q).

2. Pull back carpet and Drill 1/2” hole parallel to wall through floor along edge of wall where line meets floor for standard 14-2 w/ground

NM-B nonmetallic sheathed cable (Romex), (See Diagram R).

3. Install surface box plate on existing outlet. Feed wiring down from electrical box through track to ASLL Blower. Connect Black wire

to outlet “Hot” and White wire to outlet neutral. Connect ground wire to outlet ground wires, (See Diagram S).

DIAGRAM Q

DIAGRAM R

DIAGRAM S

MARK A VERTICAL LEVEL LINE DOWN FROM
OUTLET.

INSTALL SURFACE WIRING BOX PLATE ON
EXISTING OUTLET AND WIRE POWER FEED IN
FOR ASLL.

DRILL 1/2” HOLE PARALLEL TO WALL THROUGH
FLOOR WHERE VERTICAL LINE FROM OUTLET
MEETS FLOOR.

L1

50/60 Hz

120 VAC

N

S1

GROUND

ELECTRICAL BOX

8050019 3/19/09

MOTOR

GREEN

WHITE

BLACK

= WIRE NUTS SUPPLIED BY OTHERS

BLOWER

= WIRING SUPPLIED BY OTHERS

= OPTIONAL 120 VAC T-STAT, WALL SWITCH, ETC.

S1

RED

BLUE

= FACTORY WIRE NUT CONNECTION

AIRESHARE

TM

MODEL ASLL WIRING CONNECTIONS

Advertising