Tjernlund FV1 Crawl Space Vent 8504143 User Manual

Page 3

Advertising
background image

DIMENSIONS

TROUBLESHOOTING INSTALLATION PROBLEMS

VENT FACEPLATE DOES NOT FIT UNDER SIDING

OPTION 1: Trim the FV1 faceplate. The backside of the faceplate has pre-scored lines to assist in trimming. This
area can be trimmed using simple tools (utility knife, pliers, hacksaw) to customize the height of the faceplate. Width
trimming is usually not needed, but may be done using cutting tools made to cut ABS materials.

OPTION 2: On some homes the siding needs to be pried away from the sill plate and the foundation by a 1/8” or 1/4”
for the vent faceplate to slide under and up to the sill plate. To do this, one may use a pry bar or shims to pry the sid-
ing away from the framing and foundation. Do so with caution. Siding can be very brittle. Always secure all
loosened areas once installation is complete. If the siding is pried away and the vent still will not fit check for nails,
screws, or other obstructions.

SILL PLATE OVERHANGS THE FOUNDATION AND THE VENT DOES NOT FIT FLUSH AGAINST FOUNDATION
If the sill plate overhangs or is recessed from the foundation, use a 1x2, 2x2 or 2x4 piece of lumber cut to the length of
the opening of the foundation and attach the lumber to the sill plate so that it is flush with the foundation. This now
becomes the sill plate to which the faceplate can be mounted.

FACEPLATE IS FLUSH, THREADED RODS ARE IN THE FACEPLATE BUT THE THREADED RODS DO NOT GO
THROUGH THE PRE-DRILLED HOLES IN THE BACKER BAR; THE WING NUTS CANNOT BE ATTACHED
The included threaded rods are 9” long. These will accommodate foundation block wall widths of up to 8”. For buildings
with thicker foundations, substitute the included rod with an 1/4” diameter rod cut to the length necessary for installation.
NOTE: At least 1” of clearance is needed beyond the width of the foundation wall in order for the vent screen, winter
door, and backer bar to fit properly.

VENT OPENING IS BIGGER OR SMALLER THAN THE FV1 FACEPLATE
A frame can be built for openings too large for the faceplate or the faceplate can be cut to size for a smaller
opening.

FACEPLATE INSTALLATION

7"

10"

19 1/2"

14 1/2"

18"

2"

2"

1/2"

1"

9"

8061006 9/5/07

Advertising