1. Route the switched power load wiring from the switch to the Blower housing. Use one of the (4) provided knockouts in the Blower

housing. Route a minimum of 12" of wire inside the Blower housing. If using 14 gauge nonmetallic sheathed cable (Romex or equiva-
lent), strain relief the wiring at the Blower housing using the provided black plastic nonmetallic cable strain relief. If using some other
wire type, strain relief the wire at the Blower housing using an approved strain relief method, (See Figure L).

2. Install the dual Fan assembly into the Blower housing making sure to route all wires thru the access hole in the front of the Fan

assembly. To install the Fan assembly, hook the top edge of the Fan assembly under the 2 extruded dimples located on the top of
the Blower housing. Push the Fan assembly into the Blower housing until the assembly snaps into place, (See Figure M).

3. Wire the Fan assembly to the Timer switch wiring as defined in the wiring diagram below. Once complete, install Fan assembly elec-

trical coverplate with the screw provided and Timer switch cover plate. Install the white Intake Grille over the Blower housing with the
provided white headed screws. The grille louvers should face upwards so fans can not be viewed through the grille, (See Figure N).

MAINTENANCE

The Sure Dry™ fan compartment should be inspected annually and carefully cleaned or vacuumed with a bristle brush head if neces-
sary. The motors are permanently lubricated and require no maintenance.

REPLACEMENT PARTS AND WARRANTY

Component

Part Number

Component

Part Number

Digital Timer - White

950-9300

SD140 Dual Fan Assembly

950-9310

Intake Grille - White

950-9320

Shower Supply Grille - White

950-9321

TJERNLUND LIMITED ONE YEAR WARRANTY

Tjernlund Products, Inc. warrants to the original purchaser of this product that the product will be free from defects due to faulty material or workmanship for a period of (1)
year from the date of original purchase or delivery to the original purchaser, whichever is earlier. Remedies under this warranty are limited to repairing or replacing, at our
option, any product which shall, within the above stated warranty period, be returned to Tjernlund Products, Inc. at the address listed below, postage prepaid. THERE ARE
NO WARRANTIES WHICH EXTEND BEYOND THE DESCRIPTION ON THE FACE HEREOF, AND TJERNLUND PRODUCTS, INC. EXPRESSLY DISCLAIMS LIABILITY
FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES ARISING FROM THE USE OF THIS PRODUCT. THIS WARRANTY IS IN LIEU OF ALL OTHER EXPRESS WAR-
RANTIES AND NO AGENT IS AUTHORIZED TO ASSUME FOR US ANY LIABILITY ADDITIONAL TO THOSE SET FORTH IN THIS LIMITED WARRANTY. IMPLIED
WARRANTIES ARE LIMITED TO THE STATED DURATION OF THIS LIMITED WARRANTY. Some states do not allow limitation on how long an implied warranty lasts,
so that limitation may not apply to you. In addition, some states do not allow the exclusion or limitation of incidental or consequential damages, so that above limitation or
exclusion may not apply to you. This warranty gives you specific legal rights and you may also have other rights which may vary from State to State. Send all inquiries
regarding warranty work to Tjernlund Products, Inc. 1601 9th Street, White Bear Lake, MN 55110-6794. Phone (651) 426-2993 • (800) 255-4208 • Fax (651) 426-9547 •
Email [email protected].

GROUND

120 VAC
50/60 Hz

N

L1

SD140 FAN TIMER

JUNCTION BOX

BLACK

RED

WHITE

GFI

PROTECTED

FAN

GREEN

SD140 FAN JUNCTION BOX

WHITE

BLACK

WHITE

BLACK

FAN

WIRE NUTS

DIGITAL

TIMER

GREEN

SURE DRY

TM

MODEL SD140 FAN & TIMER WIRING CONNECTIONS

FIGURE M

FIGURE N

FIGURE L