FREEZE PROTECTION THERMOSTAT ACTIVATION RANGE

IMPORTANT: All Ventilator models are equipped with a factory installed and pre-wired thermostat which will prevent opera-
tion of the fan below 35°F outdoor temperature. Normal operation of the fan will resume once the temperature outside rises
near 50° F. NOTE: Models V1D & V2D with dehumidistat control also will not operate if the freeze protection thermostat
senses low outdoor temperatures.

WARRANTY

TJERNLUND LIMITED ONE YEAR WARRANTY

Tjernlund Products, Inc. warrants to the original purchaser of this product that the product will be free from defects due to faulty material or workmanship for a period of (1)
year from the date of original purchase or delivery to the original purchaser, whichever is earlier. Remedies under this warranty are limited to repairing or replacing, at our
option, any product which shall, within the above stated warranty period, be returned to Tjernlund Products, Inc. at the address listed below, postage prepaid. THERE ARE
NO WARRANTIES WHICH EXTEND BEYOND THE DESCRIPTION ON THE FACE HEREOF, AND TJERNLUND PRODUCTS, INC. EXPRESSLY DISCLAIMS LIABILITY
FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES ARISING FROM THE USE OF THIS PRODUCT. THIS WARRANTY IS IN LIEU OF ALL OTHER EXPRESS WAR-
RANTIES AND NO AGENT IS AUTHORIZED TO ASSUME FOR US ANY LIABILITY ADDITIONAL TO THOSE SET FORTH IN THIS LIMITED WARRANTY. IMPLIED
WARRANTIES ARE LIMITED TO THE STATED DURATION OF THIS LIMITED WARRANTY. Some states do not allow limitation on how long an implied warranty lasts, so
that limitation may not apply to you. In addition, some states do not allow the exclusion or limitation of incidental or consequential damages, so that above limitation or
exclusion may not apply to you. This warranty gives you specific legal rights and you may also have other rights which may vary from State to State. Send all inquiries
regarding warranty work to Tjernlund Products, Inc. 1601 9th Street, White Bear Lake, MN 55110-6794. Phone (651) 426-2993 • (800) 255-4208 • Fax (651) 426-9547 •
Email [email protected].

GROUND

L1

OFF

120 VAC
50/60 Hz

ON

DE-HUMIDISTAT

V1D ELECTRICAL BOX

RED

BLK

T-STAT

WHT

BLU

FAN

8050003A

GRN

20 VAC
0/60 Hz

PROVIDED BY INSTALLER

OPTIONAL ON-OFF SWITCH-OUTLET

L2

MODEL V1D INTERNAL WIRING

120 VAC
50/60 Hz

OPTIONAL ON-OFF SWITCH-OUTLET

PROVIDED BY INSTALLER

GROUND

L1

L2

OFF

50/60 Hz

120 VAC

ON

FAN

FAN

V2D ELECTRICAL BOX

DE-HUMIDISTAT

T-STAT

BLK

RED

WHT

BLU

WHT

8050004A

BLK

GRN

MODEL V2D INTERNAL WIRING