Tjernlund X2D XCHANGER Reversible Basement Fan 8504164 Rev C 07/14 User Manual

Page 7

Advertising
background image

6

11. The X

CHANGE

R

TM

comes with (2) air infiltration magnetic draft stops to block incoming air during seasons or periods when the

X

CHANGE

R

TM

is not in use if desired. Place magnet(s) over X

CHANGE

R

TM

fan opening(s) when fan is not in use to block air infiltra-

tion. Place magnet(s) on side of X

CHANGE

R

TM

cabinet so they are not lost if not in use to block fan openings, (See Diagram N).

12.

WARNING: Unplug fans from dehumidistat control when changing fan direction to prevent damage or injury. Insert fans in desired

direction for either exhaust or intake. See arrow on bottom of fan cartridge or side of fan shroud for air flow direction. Once
installed confirm the air is being exhausted or supplied depending upon application, (See Diagram O).

13. Insulate around X

CHANGE

R

TM

housing, (See Diagram P).

XCHANGER DEHUMIDISTAT CONTROL MODULE INSTALLATION & OPERATION

XCHANGER DEHUMIDISTAT CONTROL MODULE INSTALLATION & OPERATION

Install X

CHANGE

R

TM

dehumidistat control module on wall with provided screws and

wall anchors and plug X

CHANGE

R

TM

fans into side outlets.

IMPORTANT: Do not plug other devices into dehumidistat control or damage may result.
Once fans are installed in X

CHANGE

R

TM

, plug dehumidistat control into standard outlet.

The X

CHANGE

R

TM

control module includes an adjustable dehumidistat control which

activates the fan(s) if the relative humidity rises above the selected set-point. It is gener-
ally recommended to maintain a Relative Humidity (RH) below 60% to inhibit mold
growth. The dehumidistat can be turned fully clockwise to the ‘on’ position for constant
fan(s) operation or it can be turned fully counter-clockwise to ‘off’ during seasons or
times when it is not desired for the X

CHANGE

R

TM

fan(s) to run. Each X

CHANGE

R

TM

fan

is independently controlled by its own on/off switch. Turn switch(s) off during seasons
or applications where it is not desired to run that fan, (See Diagram Q).

XCHANGER LADDER DIAGRAM

DIAGRAM N

DIAGRAM O

PLACE MAGNETIC DRAFT STOPS OVER XCHANGER
FAN OPENING(S) WHEN FAN IS NOT IN USE TO
BLOCK AIR INFILTRATION IF DESIRED. PLACE ON
SIDE OF CABINET IF NOT IN USE SO THEY ARE NOT
LOST.

DIAGRAM Q

SCREW DEHUMIDISTAT CONTROL TO WALL AND
PLUG FANS INTO SIDE OUTLETS.

WARNING: UNPLUG FANS WHEN CHANGING
DIRECTION. SEE ARROW ON BOTTOM OF FAN
CARTRIDGE OR SIDE OF FAN SHROUD FOR
AIR FLOW DIRECTION.

DIAGRAM P

INSULATE AROUND XCHANGER HOUSING.

120 VAC
50/60 Hz

DE-HUMIDISTAT

CHANGE CONTROL BOX

HOT BLACK

WHITE

8050022

BLACK

NEUTRAL BLACK

BLUE

RED

RED

RED

RED

R

X

SWITCHED OUTLETS

FAN SWITCH 2

FAN SWITCH 1

XCHANGER FANS

IMPORTANT:
ONLY PLUG
XCHANGER FANS
INTO CONTROL!

FAN ON/OFF
SWITCHES