Tjernlund X2D XCHANGER Reversible Basement Fan 8504164 Rev A 05/10 User Manual

Page 2

Advertising
background image

1

TABLE OF CONTENTS

Descriptions and Specifications.......................................................................................................................................1
Installation Restrictions....................................................................................................................................................1
Cautions ..........................................................................................................................................................................2
Recommended Methods and Patterns of Operation....................................................................................................2-3
Recommended Installation and Termination Locations................................................................................................3-4
X

CHANGE

R

TM

Installation ..............................................................................................................................................4-6

Dehumidistat Control Module Installation & Operation ...................................................................................................6
X

CHANGE

R

TM

Ladder Diagram ........................................................................................................................................6

Maintenance ....................................................................................................................................................................7
How to Obtain Service & Warranty..................................................................................................................................7
Replacement Parts & Accessories ..................................................................................................................................7

X

CHANGE

R

TM

is a trademark of Tjernlund Products, Inc.

Tjernlund Products welcomes your comments and questions. Call us at (651) 426-2993, (800) 255-4208, Fax (651) 426-9547, email us
at [email protected] or write to: Customer Service, Tjernlund Products, Inc., 1601 Ninth Street, White Bear Lake, MN 55110-6794.

DESCRIPTION

The X

CHANGE

R

TM

model X2D is a dual fan mechanical ventilator capable of exhausting inside air, providing fresh outside air or provid-

ing a balanced air exchange. The fans can be independently switched on or off or be easily reversed to provide fresh outside air or
exhaust inside air. The X2D includes a dehumidistat control which operates the fan(s) based on the relative humidity sensed by the
control inside the home. The dehumidistat control includes an “On” setting that will operate the fan(s) continuously or the switch can
be turned “Off” so the fan(s) do not operate during undesireable seasons. The X

CHANGE

R

TM

can also be operated by a standard

plug-in timer. Tjernlund’s optional SCP speed control kit is also available if desired.

SPECIFICATIONS

GENERAL INFORMATION

Each X

CHANGE

R

TM

is electrically factory line tested before shipment. After opening carton, Inspect thoroughly for hidden damage.

INSTALLATION RESTRICTIONS

WARNING: Improper installation, adjustment, alterations, service or maintenance can cause injury or property damage. Refer to

this manual. For assistance or additional information consult a qualified installer, service agency or the equipment supplier.

WARNING: Sufficient air is needed for proper combustion and exhausting of gases through the flue (chimney) of fuel burning equip-

ment to prevent backdrafting. Follow the heating equipment manufacturer’s guideline and safety standards such as those
published by the National Fire Protection Association (NFPA), and the American Society for Heating, Refrigeration and

Air Conditioning Engineers (ASHRAE), and the local code authorities.

WARNING: Do not exhaust air from mechanical room unless makeup air is also supplied or equipment in mechanical room is sealed

combustion. Carbon monoxide poisoning may result. Use the DT2-6 6” duct take-off kit so exhaust can be removed from
outside the mechanical room if necessary.

Observe proper location of hood as described on page 3. The X

CHANGE

R

TM

must only be installed with the hood on an exterior wall.

Only X

CHANGE

R

TM

fans can be plugged into dehumidistat control module or damage may result.

Do not discharge intake air onto water pipes or other equipment which may be affected by temperature extremes.

MODEL X2D XCHANGER

Dehumidistat: 20% - 80% RH Range

Rough-in Wall Opening Dimensions: 12 1/4” x 5 1/4””

1 FAN

2 FANS

Voltage

120

120

Watts

20

40

Amps

0.3

0.6

CFM

90

180