Tjernlund X2R XCHANGER Reversible Basement Fan 850402 User Manual

Page 2

Advertising
background image

1

TABLE OF CONTENTS

Descriptions and Specifications.......................................................................................................................................1
Installation Restrictions....................................................................................................................................................1
Cautions .......................................................................................................................................................................1-2
Recommended Methods and Patterns of Operation....................................................................................................2-3
Recommended Installation and Termination Locations................................................................................................3-4
X

CHANGE

R

TM

Installation ..............................................................................................................................................4-6

Maintenance ....................................................................................................................................................................6
How to Obtain Service & Warranty ..............................................................................................................................6-7
Replacement Parts & Accessories ..................................................................................................................................7

X

CHANGE

R

TM

is a trademark of Tjernlund Products, Inc.

Tjernlund Products welcomes your comments and questions. Call us at (651) 426-2993, (800) 255-4208, Fax (651) 426-9547, email us
at [email protected] or write to: Customer Service, Tjernlund Products, Inc., 1601 Ninth Street, White Bear Lake, MN 55110-6794.

DESCRIPTION

The X

CHANGE

R

TM

model X2R is a dual fan mechanical ventilator capable of exhausting inside air, providing fresh outside air or provid-

ing a balanced air exchange. The fans can be independently switched on or off or be easily reversed to provide fresh outside air or
exhaust inside air. The X

CHANGE

R

TM

can be operated by a standard plug-in timer or Tjernlund’s optional DH2P dehumidistat control

which operates the fan(s) based on the relative humidity sensed inside the home. The DH2P control includes an “On” setting that will
operate the fan(s) continuously or it can be turned “Off” so the fan(s) do not operate during undesirable seasons.Tjernlund’s optional
SCP speed control kit is also available to vary speed of fans if desired. See accessories on page 7.

X2R SPECIFICATIONS

GENERAL INFORMATION

Each X

CHANGE

R

TM

is electrically factory line tested before shipment. After opening carton, Inspect thoroughly for hidden damage.

INSTALLATION RESTRICTIONS

WARNING: Improper installation, adjustment, alterations, service or maintenance can cause injury or property damage. Refer to

this manual. For assistance or additional information consult a qualified installer, service agency or the equipment supplier.

WARNING: Sufficient air is needed for proper combustion and exhausting of gases through the flue (chimney) of fuel burning equip-

ment to prevent backdrafting. Follow the heating equipment manufacturer’s guideline and safety standards such as those
published by the National Fire Protection Association (NFPA), and the American Society for Heating, Refrigeration and

Air Conditioning Engineers (ASHRAE), and the local code authorities.

WARNING: Do not exhaust air from mechanical room unless makeup air is also supplied or equipment in mechanical room is sealed

combustion. Carbon monoxide poisoning may result. Use the DT2-6 6” duct take-off kit so exhaust can be removed from
outside the mechanical room if necessary.

Observe proper location of hood as described on page 3. The X

CHANGE

R

TM

must only be installed with the hood on an exterior wall.

Do not discharge intake air onto water pipes or other equipment which may be affected by temperature extremes.

CAUTIONS

WARNING: Failure to install, maintain and/or operate the X

CHANGE

R

TM

in accordance with manufacturer’s instructions may result in

conditions that can produce bodily injury and property damage.

MODEL X2R XCHANGER

Rough-in Wall Opening Dimensions:
13 1/4” x 6 1/2” Oval opening - utilize included template

8061034

FLEXIBLE TUBING

NOMINAL 6" DIAMETER

BY INSTALLER

1 FAN

2 FANS

Voltage

120

120

Watts

20

40

Amps

0.3

0.6

CFM

90

180

Advertising